Force plate monitoring of human hemodynamics

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Force plate monitoring of human hemodynamics

BACKGROUND Noninvasive recording of movements caused by the heartbeat and the blood circulation is known as ballistocardiography. Several studies have shown the capability of a force plate to detect cardiac activity in the human body. The aim of this paper is to present a new method based on differential geometry of curves to handle multivariate time series obtained by ballistocardiographic for...

متن کامل

طراحی سکونیرو ‏‎(force plate)‎‏

تجزیه و تحلیل گیت ‏‎(gait analysis)‎‏عبارت است از تحقیق روی راه رفتن از نظر حرکت اندامها می باشد، در این بررسی می توان مواردی نظیر کنترل موقعیت، سینتیک و سینماتیک بدن ، کنترل بدن و کنترل عصبی را در نظر داشت. اینگونه تحقیقات در ارتوپدی ، بیومکانیک ورزش و عصب شناسی و کاربرد دارند. پارامترهای مهم در اینگونه تحقیقات عبارت از نیرو ، ممان ، سرعت ، مصرف انرژی و فشار کف پا می باشند. سه روش برای اندازه ...

15 صفحه اول

Human Postural Control : Force Plate Experiments

We report the results of time series analysis of human body sway while quiet upright stance. The bivariate records (stabilograms) are measured by means of a force plate. To investigate interrelations between oscillations in anterior{posterior and lateral directions we use several techniques: cross-spectrum analysis, generalized mutual information, and calculation of instantaneous relative phase...

متن کامل

Human Postural Control | Force Plate Experiments and Modelling

We report the results of time series analysis of human body sway while quiet upright stance. The bivariate records (stabilograms) are measured by means of a force plate. To investigate interrelations between oscillations in anterior{posterior and lateral directions we use several techniques: cross{spectrum analysis, generalized mutual information, and calculation of instantaneous relative phase...

متن کامل

Wireless Monitoring of Liver Hemodynamics In Vivo

Liver transplants have their highest technical failure rate in the first two weeks following surgery. Currently, there are limited devices for continuous, real-time monitoring of the graft. In this work, a three wavelengths system is presented that combines near-infrared spectroscopy and photoplethysmography with a processing method that can uniquely measure and separate the venous and arterial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nonlinear Biomedical Physics

سال: 2008

ISSN: 1753-4631

DOI: 10.1186/1753-4631-2-1