Force Measurement Time-Delays and Contact Instability Phenomenon

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scanning speed phenomenon in contact-resonance atomic force microscopy

This work presents data confirming the existence of a scan speed related phenomenon in contact-mode atomic force microscopy (AFM). Specifically, contact-resonance spectroscopy is used to interrogate this phenomenon. Above a critical scan speed, a monotonic decrease in the recorded contact-resonance frequency is observed with increasing scan speed. Proper characterization and understanding of th...

متن کامل

Preventing Instability Phenomenon in Gas-lift Optimization

One of the problems that sometimes occur in gas allocation optimization is instability phenomenon. This phenomenon reduces the oil production and damages downhole and surface facilities. Different works have studied the stability and suggested some solutions to override it, but most of them (such as making the well intelligent) are very expensive and thus they are not applicable to many cases. ...

متن کامل

Real-time contact force measurement: a key parameter for controlling lesion creation with radiofrequency energy.

R adiofrequency (RF) energy, the dominant energy source for the treatment of various arrhythmias by catheter abla-tion, has replaced most other treatments for the effective suppression of supraventricular and ventricular arrhythmias. 1 With expanding indications, it has become increasingly clear that the success and sustainable effect of RF ablation depends on a critical understanding of the bi...

متن کامل

Measurement of Poisson’s ratio with contact- resonance atomic force microscopy

We describe contact-resonance atomic force microscopy ͑AFM͒ methods to quantitatively measure Poisson's ratio ␯ or shear modulus G at the same time as Young's modulus E. In contact-resonance AFM, the frequencies of the cantilever's resonant vibrations are measured while the tip is in contact with the sample. Simultaneous measurement of flexural and torsional vibrational modes enables E and ␯ to b...

متن کامل

Measurement of palatolingual contact pressure and tongue force using a force-sensor-mounted palatal plate

In this paper, we report on a 15-cantilever-type, force-sensormounted palatal plate capable of high sensitivity and accurate measurements of the palatolingual contact pressure and pattern that occur during consonant phonation. This paper also describes measurements of tongue force based on the results of the palatolingual contact pressure measurements that the 15-cantilever-type, force-sensor-m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Journal of Control

سال: 1999

ISSN: 0947-3580

DOI: 10.1016/s0947-3580(99)70163-9