Fogarty Balloon Dilatation for Intraoperative Arterial Spasm

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative Balloon Angioplasty Using Fogarty Artertial Embolectomy Balloon Catheter for Creation of Arteriovenous Fistula for Hemodialysis: Single Center Experience

BACKGROUND The purpose of this study was to evaluate the use of a Fogarty arterial embolectomy catheter (Fogarty catheter) in intraoperative balloon angioplasty of the cephalic vein, in order to determine its effect on the patency of arteriovenous fistulas (AVFs) created for hemodialysis access. METHODS A total of 156 patients who underwent creation of an AVF were divided into two groups, bas...

متن کامل

Percutaneous balloon valve dilatation.

opting out would negate much of the enterprise. The public must be told repeatedly about the likely consequences of the proposals, and the BMA council has launched this exercise. And negotiation must take place-and on equal terms, with flexibility and without the duress of a short timetable which owes more to political expediency than to the issues at stake. In the negotiations the BMA and the ...

متن کامل

Intra-aortic balloon pump for oesophageal dilatation.

We read with interest the article by Loubani et al. [1] regarding the use of intra-aortic balloon pumps (IABP) for dilating oesophageal strictures. There are fundamental reasons why IABP is not the instrument of choice for oesophageal dilatation, even in difficult cases. IABP was never designed as a dilator. Its function is to produce diastolic augmentation of coronary and systemic blood flow b...

متن کامل

Percutaneous aortic balloon dilatation for calcific

Eight elderly patients (mean (SD) age 72-6 (8&5) years) with severe calcified stenosis of the aortic valve were considered for transluminal balloon dilatation in the Thoraxcenter between March and November 1986. In one patient the procedure could not be performed because of technical difficulties. Balloons of increasing diameter (13-25 mm) were successively passed retrogradely from the femoral ...

متن کامل

Balloon dilatation for male urethral strictures “revisited”

AIMS To analyze the results of balloon dilatation for short segment male urethral strictures. MATERIALS AND METHODS Retrospective analysis was done of 120 patients undergoing urethral balloon dilatation since January 2004 to January 2012. The inclusion criteria for analysis was a short segment (less than 1.5 cm) stricture, exclusion criteria were pediatric, long (more than 1.5 cm), traumatic,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Journal of Vascular and Endovascular Surgery

سال: 2000

ISSN: 1078-5884

DOI: 10.1053/ejvs.1999.1062