FOCAL SPOT SIZE AND SEPARATION IN STEREOSCOPIC MAGNIFICATION RADIOGRAPHY (II. Radiographic Technology for Stereoscopic Magnification)
نویسندگان
چکیده
منابع مشابه
Stereoscopic magnification in spinal angiography.
This technique combines the advantages of magnification and stereoscopic angiography. A heavy-duty x-ray tube oscillating between two positions (25 mm apart) allows serial spinal angiograms to be produced in stereo magnification (factor 2.0) using the 0.2 mm, 12 kW focal spot. The x-ray tube can be rapidly changed for normal serial angiography with a 0.6 mm, 50 kW focus. The technique is easy t...
متن کاملStomach and duodenum: radiographic magnification using computed radiography (CR).
We performed direct radiographic magnification (X3) using a 0.1-mm microfocal tube and computed radiography (CR) in air-barium double-contrast studies of the stomach and duodenum. To eliminate blurring of the image due to motion, we used the maximum kilovolt peak rate possible (102 kVp), the maximum milliampere second rate possible (64 mAs), the shortest possible exposure time (0.1 second), and...
متن کاملEvaluation of Image Magnification in Digital Panoramic Radiography
Introdouction: The aim of the present study was to investigate image magnification in digital panoramic radiography and assess the effect of anatomical sites on the magnification in both males and females. Materials and methods: In this retrospective study, digital panoramic radiographs of 48 patients with 202 implants were investigated. Implant diameter and length were measured on pan...
متن کاملForbidden magnification? II
The twin of this paper, “Forbidden Magnification? I.” [1], presents systematic SOM simulations with the explicit magnification control scheme of Bauer, Der, and Herrmann [2] on data for which the theory does not guarantee success, namely data that are n-D, n > 2 and/or data whose components in the different dimensions are not statistically independent. For the unsupported n = 2 cases that we in...
متن کاملSize estimation and magnification error in radiographic imaging: implications for classification of arteriovenous malformations.
PURPOSE To assess magnification error in digital subtraction angiography as it pertains to arteriovenous malformation (AVM) size. METHODS A rectangular grid phantom with equally spaced markers mounted in a stereotactic frame was imaged with digital angiographic equipment. The location and orientation of the grid was altered relative to the central plane of the phantom. Both linear and area me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1983
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003106685