Foam Fluid Flow Analysis in Helical Coiled Tubing Using CFD
نویسندگان
چکیده
منابع مشابه
Numerical Analysis of a Helical Coiled Heat Exchanger using CFD
Heat exchangers are the important equipments with a variety of industrial applications including power plants, chemical, refrigeration and air conditioning industries. Helically coiled heat exchangers are used in order to obtain a large heat transfer area per unit volume and to enhance the heat transfer coefficient on the inside surface. This paper deals with the CFD simulation of helical coile...
متن کاملCFD-Calculation of Fluid Flow in a
An accurate description of the fluid flow and heat transfer within a Pressurized Water Reactor (PWR), for the safety analysis and reactor performance is always desirable. In this paper a mathematical model of the fundamental physical phenomena which are associated to a typical PWR is presented. The mathematical model governs the fluid dynamics in the reactor. Using commercial software CFX, a co...
متن کاملComparison of convective heat transfer of turbulent nanofluid flow through helical and conical coiled tubes
Application of nanofluid and coiled tubes are two passive methods for increasing the heat transfer. In the present study, the turbulent flows of water and nanofluid in coiled tubes heat exchanger were numerically studied. CuO-water nanofluid containing 1 vol% copper oxide nanoparticles was used and single-phase approach was considered for nanofluid flow. The effect of different geometrical para...
متن کاملBiocide-mediated corrosion of coiled tubing
Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons d...
متن کاملFluid Flow and Heat Transfer Analysis of the Vhtr Lower Plenum Using the Fuego Cfd Code
There are a number of safety and heat transfer issues in the lower plenum (LP) of a prismatic core very high temperature reactor (VHTR), such as the formation of hot spots in the lower support plate and thermal stratification of the helium gas coolant. In this paper, results of key separate-effect validation and verification (V&V) calculations, as well as the calculated flow fields and heat tra...