Fluorometric determination of kynurenic acid in urine with zinc(II) acetate.
نویسندگان
چکیده
منابع مشابه
Direct fluorometric determination of urea in urine.
Urea in biological fluids has been determined by a variety of direct and indirect procedures. Some indirect methods depend on the hydrolysis of urea with the enzyme urease to form ammonia, with subsequent quantitation of the ammonia by nesslerization (1-4). Undesirable features of these indirect methods are the use of relatively unstable reagents and loss of ammonia during the procedure. Direct...
متن کاملAutomated fluorometric determination of amphetamine in urine.
A completely automated fluorometric determination of amphetamine in urine is described and evaluated. The dihydrolutidine derivative produced by reaction of amphetamine with formaldehyde and acetylacetone is excited at 410 nm and the resulting intensity of fluorescence measured at 476 nm. The working limit of detection of amphetamine in fresh urine (1.5-mi samples) is 0.15 mg/liter. A result is...
متن کاملRapid fluorometric estriol determination in pregnancy urine.
curves of precipitation are shown in Figure 1. Ampicillin, carbenicillin, amoxycillin, procaine penicillin, cephalothin, salicylic acid, acetylsalicylic acid, and dexamethasone caused no interference. The presence of methicillin in urine may be differentiated from the turbidity attributable to protein by measuring the absorbance at different intervals during the reaction, such as 0.5 and 5.0 mm...
متن کاملThe fluorometric determination of malic acid.
A sensitive and specific chemical method for the estimation of malic acid in biological materials has long been desired. The condensation of malic acid with orcinol in the presence of concentrated sulfuric acid to form the highly fluorescent homoumbelliferone (7-hydroxyd-methylcoumarin) was reported years ago (1). Although this reaction is relatively specific for malic acid, the quantitative pr...
متن کاملAcid in Human Determination Urine
An ion pair reversed phase HPLC method for the determination of clavulanic acid has been developed. Since clavulanic acid had poor absorption O,mas 201 nm in water) in a UVregion suitable for HPLC detection, the detectability was enhanced by bathochromic shift of )maa due to solvent effect. The shifts of 2ma.., were measured with the solutions containing clavulanic acid, tetrabutylammonium brom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1985
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.34.8_483