Fluorescent Probe for Ag+ Detection Using SYBR GREEN I and C-C Mismatch
نویسندگان
چکیده
منابع مشابه
Large flanking sequence effects in single nucleotide mismatch detection using fluorescent nucleoside C(f).
The first systematic study of flanking sequence effects on mismatch detection by a fluorescent nucleotide is described, using fluoroside C(f). Although a high degree of variance was observed in fluorescence intensity of mismatched duplexes between different flanking sequences, C(f) was able to distinguish a mismatch from the fully base-paired duplex in 13 out of 16 sequences, and even identify ...
متن کاملA mismatch-selective bifunctional rhodium-Oregon Green conjugate: a fluorescent probe for mismatched DNA.
A fluorescent metallointercalator conjugate that selectively targets DNA base mismatches has been synthesized by coupling an organic fluorophore to a bulky Rh intercalator containing the chrysenequinone diimine ligand. Ion pairing between the cationic Rh and anionic fluorophore moieties dramatically quenches the fluorescence of the conjugate in solution and in the presence of matched DNA. Howev...
متن کاملDevelopment of SYBR Green I Based Real-Time RT-PCR Assay for Specific Detection of Watermelon silver mottle Virus
Background: Watermelon silver mottle virus (WSMoV), which belongs to the genus Tospovirus, causes significant loss in Cucurbitaceae plants. Objectives: Development of a highly sensitive and reliable detection method for WSMoV. Materials and Methods: Recombinant plasmids for targeting the sequence of nucleocapsid protein gene of WSMoV were constructed. SYBR Green I real-time PCR was established...
متن کاملDetection of a single DNA base-pair mismatch using an anthracene-tagged fluorescent probe.
A novel anthracene-tagged oligonucleotide can discriminate between a fully-matched DNA target sequence and one with a single mismatching base-pair through a remarkable difference in fluorescence emission intensity upon duplex formation.
متن کاملA real-time PCR assay for the detection and quantitation of Campylobacter jejuni using SYBR Green I and the LightCycler.
Campylobacter jejuni is recognized as a leading human food-borne pathogen. Traditional biochemical identification for C. jejuni is not reliable due to special growth requirements and the possibility that this bacterium can enter a viable but nonculturable (VNC) state. Nucleic acid-based tests have emerged as a useful alternative to traditional testing. In this article, we present fluorescent qu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biosensors
سال: 2020
ISSN: 2079-6374
DOI: 10.3390/bios11010006