Fluorescence lifetime imaging microscopy: Pixel-by-pixel analysis of phase-modulation data
نویسندگان
چکیده
منابع مشابه
Fluorescence Lifetime Imaging Microscopy (FLIM) Data Analysis with TIMP
Fluorescence Lifetime Imaging Microscopy (FLIM) allows fluorescence lifetime images of biological objects to be collected at 250 nm spatial resolution and at (sub-)nanosecond temporal resolution. Often ncomp kinetic processes underlie the observed fluorescence at all locations, but the intensity of the fluorescence associated with each process varies per-location, i.e., per-pixel imaged. Then t...
متن کاملA 256 x 256 SPAD array with in-pixel Time to Amplitude Conversion for Fluorescence Lifetime Imaging Microscopy
A high resolution Time Correlated Single Photon Counting (TCSPC) image sensor based on sample and hold Time to Amplitude Converter (TAC)pixels and a global ramp voltage is presented. The 256× 256 array achieves an 8 μm Pixel Pitch (PP), 19.63% Fill Factor (FF), output voltage range (0.7V) and time jitter of 368 ps at 10 fps employing an off-chip 14-bit differential Analogue to Digital Converter...
متن کاملFluorescence colocalization microscopy analysis can be improved by combining object‐recognition with pixel‐intensity‐correlation
The question whether two proteins interact with each other or whether a protein localizes to a certain region of the cell is often addressed with fluorescence microscopy and analysis of a potential colocalization of fluorescence markers. Since a mere visual estimation does not allow quantification of the degree of colocalization, different statistical methods of pixel-intensity correlation are ...
متن کاملPer-Pixel Lighting Data Analysis
This report presents a framework for per-pixel analysis of the qualitative and quantitative aspects of luminous environments. Recognizing the need for better lighting analysis capabilities and appreciating the new measurement abilities developed within the LBNL Lighting Measurement and Simulation Toolbox, “Per-pixel Lighting Data Analysis” project demonstrates several techniques for analyzing l...
متن کاملPhoton budget analysis for fluorescence lifetime imaging microscopy.
We have constructed a mathematical model to analyze the photon efficiency of frequency-domain fluorescence lifetime imaging microscopy (FLIM). The power of the light source needed for illumination in a FLIM system and the signal-to-noise ratio of the detector have led us to a photon "budget." These measures are relevant to many fluorescence microscope users and the results are not restricted to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bioimaging
سال: 1994
ISSN: 0966-9051,1361-6374
DOI: 10.1002/1361-6374(199409)2:3<139::aid-bio4>3.0.co;2-t