Fluid–Structure Coupling Effects in a Dual U-Tube Coriolis Mass Flow Meter

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Sub-Optimal Look-Up Table Based on Fuzzy System to Enhance the Reliability of Coriolis Mass Flow Meter

Coriolis mass flow meters are one of the most accurate tools to measure the mass flow in the industry. However, two-phase mode (gas-liquid) may cause severe operating difficulties as well as decreasing certitude in measurement. This paper presents a method based on fuzzy systems to correct the error and improve the reliability of these sensors in the presence of two-phase model fluid. Definite ...

متن کامل

Compact Mass Flow Meter Based on a Micro Coriolis Flow Sensor

In this paper we demonstrate a compact ready-to-use micro Coriolis mass flow meter. The full scale flow is 1 g/h (for water at a pressure drop < 1 bar). It has a zero stability of 2 mg/h and an accuracy of 0.5% reading for both liquids and gases. The temperature drift between 10 and 50 °C is below 1 mg/h/°C. The meter is robust, has standard fluidic connections and can be read out by means of a...

متن کامل

Coriolis Flow meter: A Review from 1989 to 2014

A consolidation of literature indicating the advances in the field of mass flow measurement is presently not available. Last published review paper on Coriolis mas flow meter (CFM) was in 2006. This work is an attempt is made to summarize the available works on Coriolis mass flow meter. The literature is classified into three major groups. The first group gives the summary of construction and t...

متن کامل

Correcting a Coriolis Meter for Two Phase Oil & Gas Flow

It is also common for flowmeters to be installed downstream of a two or three phase separator. If the well conditions change or the separator has been incorrectly sized, then it is possible that the oil liquid outlet may have some gas carry under. The effects of gas entrainment on the output of ultrasonic and Coriolis meters has been reported previously [1] [2]. It is already known that gas ent...

متن کامل

a sub-optimal look-up table based on fuzzy system to enhance the reliability of coriolis mass flow meter

coriolis mass flow meters are one of the most accurate tools to measure the mass flow in the industry. however, two-phase mode (gas-liquid) may cause severe operating difficulties as well as decreasing certitude in measurement. this paper presents a method based on fuzzy systems to correct the error and improve the reliability of these sensors in the presence of two-phase model fluid. definite ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2021

ISSN: 1424-8220

DOI: 10.3390/s21030982