Fluid dynamical drag coefficient on the octagonal-pyramid-net relative to Reynolds number.
نویسندگان
چکیده
منابع مشابه
Investigation of Drag Coefficient at Subcritical and Critical Reynolds Number Region for Circular Cylinder with Helical Grooves
Drag reduction of an object is the major concern in many engineering applications. Experimental studies have been carried out on circular cylinder with helical grooves in a subsonic wind tunnel. Different cases of helical grooves with different pitches, helical groove angles and number of starts of helical groove on circular cylinder are tested. Experimental results show the drag coefficient is...
متن کاملThe Lift and Drag on a Flat Plate at Low Reynolds Number via Variational Methods* By
The problem of determining the low Reynolds number lift and drag on a flat plate in Oseen flow is treated by the application of a variational principle due to Levine and Schwinger. This approach circumvents the difficulty which has limited previous results to drastically low values of the Reynolds number. In particular, an asymptotic form for the drag coefficient is derived, and found to be sui...
متن کاملRELATIVE INFORMATION FUNCTIONAL OF RELATIVE DYNAMICAL SYSTEMS
In this paper by use of mathematical modeling of an observer [14,15] the notion of relative information functional for relative dynamical systemson compact metric spaces is presented. We extract the information function ofan ergodic dynamical system (X,T) from the relative information of T fromthe view point of observer χX, where X denotes the base space of the system.We also generalize the in...
متن کاملDrag coefficient and strouhal number analysis of a rectangular probe in a two-phase cross flow
In some case of laboratory and industrial applications, various kind of measurement instruments must be placed in a conduit, in which multiphase fluid flows. Vortex shedding for any immersed body in flow field is created with a frequency, which according to flow conditions such as flow rates, geometry of body, etc. may be constant or variable. Failure may happen, if this frequency is close to o...
متن کاملDrag coefficient and strouhal number analysis of cylindrical tube in two phase flow
In many industrial equipment such as boilers and heat exchangers, the cylindrical tubes are exposed to the gas- liquid two phase flow. For any immersed body in flow field vortex shedding is created with a frequency that may be constant or variable, according to conditions such as flow rates, geometry of body, and etc. The failure will happen in the equipment, when this frequency is close to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NIPPON SUISAN GAKKAISHI
سال: 1990
ISSN: 1349-998X,0021-5392
DOI: 10.2331/suisan.56.1203