Flow through a channel with two-dimensional repeated square ribs. (1st report. Classification of the flow pattern).

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the thermo-hydraulic behavior of the fluid flow over a square ribbed channel

The thermo-hydraulic behavior of the air flow over a two dimensional ribbed channel wasnumerically investigated in various rib-width ratio configurations (B/H=0.5-1.75) atdifferent Reynolds numbers, ranging from 6000 to 18000. The capability of differentturbulence models, including standard k-ε, RNG k-ε, standard k-ω, and SST k-ω, inpredicting the heat transfer rate was compared with the experi...

متن کامل

Two-Dimensional Flow Analysis of Nanofluid through a Porous Channel with Suction/Injection at Slowly Expanding/Contracting Walls using Variation of Parameter Method

In this work, variation of parameter method is applied to study two-dimensional flow of nanofluid in a porous channel through slowly deforming walls with suction or injection. The results of the developed approximate analytical solution using the variation of parameter method is verified with the results of numerical solution using fourth-order Runge-Kutta method coupled with shooing techniques...

متن کامل

A Novel Structure for Optical Channel Drop Filter using Two-Dimensional Photonic Crystals with Square Lattice

In the present paper a novel structure for optical channel drop filter (CDF) based on photonic crystal ring resonator with circular core has been proposed. In order to design the proposed CDF, the plan wave expansion (PWE) method is applied for calculation of band structure and photonic band gap while the transmission characteristics of proposed CDF have been calculated using the finite differe...

متن کامل

investigation of the thermo-hydraulic behavior of the fluid flow over a square ribbed channel

the thermo-hydraulic behavior of the air flow over a two dimensional ribbed channel wasnumerically investigated in various rib-width ratio configurations (b/h=0.5-1.75) atdifferent reynolds numbers, ranging from 6000 to 18000. the capability of differentturbulence models, including standard k-ε, rng k-ε, standard k-ω, and sst k-ω, inpredicting the heat transfer rate was compared with the experi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B

سال: 1989

ISSN: 0387-5016,1884-8346

DOI: 10.1299/kikaib.55.2181