FLOW OF A RAREFIED GAS WITH THERMAL CREEP IN A CIRCULAR TUBE
نویسندگان
چکیده
منابع مشابه
Flow Visualization Around a Non - Circular Tube
The flow behavior around a cam shaped tube in cross flow has been investigated experimentally using flow visualization and pressure distribution measurement. The range of attack angle and Reynolds number based on an equivalent circular diameter are within 0 ≤ α ≤ 360˚ and 2 x 104 < Reeq < 3.4 x 104, respectively. The pressure drag features are clarified in relation to the flow behavior around t...
متن کاملPULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW
Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...
متن کاملThermal creep of a rarefied gas on the basis of non-linear Korteweg-theory
The study of thermal transpiration or more commonly called thermal creep is accomplished by use of Korteweg’s theory of capillarity. Incorporation of this theory into the balance laws of continuum mechanics allows resolution of boundary value problems via solutions to systems of ordinary differential equations.
متن کاملOne-way Flow of a Rarefied Gas Induced in a Circular Pipe with a Periodic Temperature Distribution
The steady behavior of a rarefied gas in a circular pipe with a saw-like temperature distribution increasing and decreasing periodically in the direction of the pipe axis is investigated numerically by means of the direct simulation Monte Carlo method. It is shown that a steady one-way flow is induced in the pipe without the help of a pressure gradient for a wide range of the Knudsen number whe...
متن کاملThermal Loading of a Direct Drive Target in Rarefied Gas
In an inertial fusion energy (IFE) power plant, each fusion micro-explosion (~10 Hz) causes thermal and structural loads on the IFE reactor wall and driver optics. The loading on the wall must remain sufficiently low to ensure that economic and safety constraints are met. One proposed method for decreasing the intensity of the wall loading is to fill the reaction chamber with a gas, such as Xe,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
سال: 1974
ISSN: 0021-9592,1881-1299
DOI: 10.1252/jcej.6.481