Abstract The removal of droplets on surfaces by an (air-) flow is relevant, e.g., for cleaning processes or to prevent corrosion damage electronic devices. Still the condition droplet movement not fully understood. Droplets start move downstream at a critical velocity v crit . For increasing velocity, this process related strong oscillation droplet. This supposed be key mechanism onset in conjunction with field around We report measurements wake adhering means laser-Doppler profile sensor and hot wire anemometry. Thanks excellent spatial temporal resolution its capability measure bidirectional flows, backflow region can detected Therefore, it concluded that structure driving inside against channel direction found previous work. Analyzing frequency spectra was also oscillating; peaks are same range as contour oscillation. Based frequency, diameter Strouhal number calculated. almost constant investigated regime volumes between 0.015 0.03. assumed aeroelastic self-excitation effect may present eventually leads movement. Graphic abstract
منابع مشابه
Laser Doppler Velocity Profile Sensor: Technical Advances for the Optical Flow Rate Measurement of Natural Gas
− The precise measurement of the flow rate of natural gas is of vital economical importance since natural gas contributes highly to the total energy mix. In this paper we report about a laser Doppler velocity profile sensor specifically designed to suit the measurement conditions at the optical test facility of the German natural gas flow rate standard. The profile sensor is an extension of the...
متن کاملVelocity Characteristics in the Wake of an Oscillating Cylinder
This thesis describes the results of over 2000 experimental runs conduced at the MIT Ship Model Testing Tank. A rake of constant temperature anemometers is employed to study the spanwise velocity correlation and the vertical velocity profile downstream of a vibrating cylinder. Experiments involve either free vibration implemented through a force feedback system or forced sinusoidal motion. All ...
متن کاملcomparison of blood flow velocity changes in posterior cerebral artery measured with transcranial doppler sonography in migraineurs with visual aura and normal persons after photostimulation
چکیده ندارد.
15 صفحه اولDoppler analysis of flow velocity profile at the aortic root.
This study of aortic root flow velocity profiles suggests that the flow velocity pattern is parabolic rather than flat as has been widely supposed. To analyze the distribution of flow velocity, a special ultrasound pulsed Doppler velocity flow meter, with a direct probe on the aortic wall, was designed. Sixteen patients, none with a diagnosis of aortic valve disease, were examined just before u...
متن کاملLaser Doppler flow measurements with a semiconductor laser.
In their report on laser Doppler flow measurements (J. Biomed. Eng. 1985, 7, 225) Boggett et al. compared, among other things, three different light sources for use in a laser Doppler device. The aim of that study was to distinguish between Doppler shifted and non-shifted backscattered light to obtain a flow dependent signal, which is not caused by intensity fluctuations due to number fluctuati...