Flow injection potentiometric determination of chlorpromazine

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine

A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowin...

متن کامل

Ion-selective electrodes for potentiometric determination of ranitidine hydrochloride, applying batch and flow injection analysis techniques.

New ranitidine hydrochloride (RaCl)-selective electrodes of the conventional polymer membrane type are described. They are based on incorporation of ranitidine-tetraphenylborate (Ra-TPB) ion-pair or ranitidine-phosphotungstate (RaPT) ion-associate in a poly(vinyl chloride) (PVC) membrane plasticized with dioctylphthalate (DOP) or dibutylphthalate (DBP). The electrodes are fully characterized in...

متن کامل

Flow injection potentiometric determination of Fe ( III ) using a fluoride - selective electrode as detector *

Flow injection analysis (FIA) system incorporating a fluoride ion-selective electrode (FISE) as detector is described. Laboratory-built cascade flow cell equipped with FISE and reference electrode is used for flow injection potentiometric determination of Fe(III) based on monitoring of the formation of FeF2 in acid solution. Under optimized flow conditions (4.0 mL min–1, 300 μL samples, 10–5 mo...

متن کامل

Determination of chloride in admixtures and aggregates for cement by a simple flow injection potentiometric system.

A simple flow injection system using three 3-way solenoid valves as an electric control injection valve and with a simple home-made chloride ion selective electrode based on Ag/AgCl wire as a sensor for determination of water soluble chloride in admixtures and aggregates for cement has been developed. A liquid sample or an extract was injected into a water carrier stream which was then merged w...

متن کامل

Flow Injection System with Potentiometric Detection for the Determination of Urea Content in Milks

Two variant manifolds of a flow injection analysis (FIA) system are described for the determination of urea content in milks. This determination consists of the enzymatic reaction of urea with urease in which ammonium ion is formed. Ammonium is converted to ammonia by adding a NaOH solution and then led to a gas diffusion unit in which it diffuses to an acceptor channel (Tris/HCl, pH 7.5). Here...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Pharmaceutical and Biomedical Analysis

سال: 2006

ISSN: 0731-7085

DOI: 10.1016/j.jpba.2006.03.027