Flow-Injection and Sequential-Injection Determinations of Paracetamol in Pharmaceutical Preparations Using Nitrosation Reaction

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-injection and sequential-injection determinations of paracetamol in pharmaceutical preparations using nitrosation reaction.

A simple FI and two different SI systems have been investigated for the determination of paracetamol by employing a simple reagent for a nitrosation reaction. It is based on the on-line nitrosation of paracetamol with sodium nitrite in an acidic medium. The formed nitroso derivative species reacts further with sodium hydroxide to convert it to a more stable compound. The yellow product is conti...

متن کامل

Flow-Injection Iodimetric Determination of Captopril in Pharmaceutical Preparations

Um procedimento simples, rápido e de baixo custo é descrito para a determinação de captopril em preparações farmacêuticas. O procedimento é baseado em um sistema de análises por injeção em fluxo explorando a formação em linha de triiodeto, o qual é consumido na presença do analito gerando um sinal transiente. Resposta linear foi observada até 200 μmol L com limite de detecção de 1,0 μmol L (99,...

متن کامل

Normal and reverse flow injection–spectrophotometric determination of thiamine hydrochloride in pharmaceutical preparations using diazotized metoclopramide

Simple and sensitive normal and reverse flow injection methods for spectrophotometric determination of thiamine hydrochloride (THC) at the microgram level were proposed and optimized. Both methods are based on the reaction between THC and diazotized metoclopramide in alkaline medium. Beer's law was obeyed over the range of 10-300 and 2-90 μg/mL, the limits of detection were 2.118 and 0.839 μg/m...

متن کامل

Bromide Determination in Pharmaceutical Preparations Using Indirect Gas-Diffusion Flow Injection Method with Amperometric Detector

The indirect gas-diffusion flow injection method (FI) was modified, optimized and successfully applied to bromide determination in various samples such as active substances, drugs, organic substances and water samples. The method is based on the oxidation of bromide to bromine in acidic medium, which diffuses through PTFe membrane into the acceptor flow that carried bromine to the amperometric ...

متن کامل

Determination of thiamine in pharmaceutical preparations by sequential injection renewable surface solid-phase spectrofluorometry.

Fluorometric determination of thiamine requires the conversion of the analyte to fluorescent thiochrome by hexacyanoferrate(III) oxidation in alkaline solution and the isolation of the produced thiochrome from the reaction medium by solvent extraction. It was observed that thiochrome could be concentrated and separated from the reaction medium by solid-phase extraction. The thiochrome sorpted o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2004

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.20.837