Flow Injection Analysis With Trimetazidine Dihydrochloride Ion-Selective Electrode
نویسندگان
چکیده
منابع مشابه
Measurements with fluoride ion selective electrode
Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...
متن کاملNaproxen Interference with the Ion-Selective Electrode
electrochemical: Yellow Springs Instrument Co., Yellow Springs, OH 45387) for assaying galactose. For both fluorometric procedures, all reagents and standards were prepared as previously described (1). The manual assay requires 400 jiL of Tris buffer (10 mmolJL); 600 ,iiL of a solution containing p-hydroxyphenylacetic acid (50 mg/ L) and horseradish peroxidase (EC 1.11.1.7) (10 mgIL); 160 1zL o...
متن کاملLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملChromium (III) ion selective electrode based on di(benzylamino)glyoxime
A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of
متن کاملKetoprofen ion-selective electrode and its application to pharmaceutical analysis.
The composition of a polymeric potential-determining phase for ketoprofen selective electrode has been determined and the following basic electrode parameters were examined: measurement range, slope characteristic, limit of detection, response time, lifetime and selectivity coefficients in relation to some organic and inorganic anions. The electrode have been used for ketoprofen determination i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientia Pharmaceutica
سال: 2005
ISSN: 2218-0532
DOI: 10.3797/scipharm.aut-05-14