Flow-injection determination of thyroxine using immobilized enzyme with tris(2,2'-bipyridyl)ruthenium(III) chemiluminescence detection.

A flow-injection method is reported for the determination of thyroxine based on its enhancement effect on the tris(2,2'-bipyridyl)ruthenium(III) chemiluminescence reaction in the presence of NADH using immobilized alcohol dehydrogenase purified from baker yeast. The limit of detection (3 sigma blank) was 5.0 x 10(-8) M with a sample throughput of 80 h(-1). The calibration graph was linear over ...

متن کامل

Immobilized enzymes in flow-injection analysis: present and trends

An overview of the use of immobilized enzymes in flow-injection analysis (FIA) is presented. The joint use of FIA and immobilized enzymes means that analytical procedures are easily automated, analytical costs are reduced and methods are faster. The future possibilities for this combination are discussed.

متن کامل

Enzymatic Flow Reactor for Immobilized Enzyme Processes

Strem Chemicals, Inc. 7 Mulliken Way Newburyport, MA 01950-4098 U.S.A. Tel.: (978) 499-1600 Fax: (978) 465-3104 Email: [email protected] Strem Chemicals, Inc. 15, rue de l’Atome Zone Industrielle 67800 BISCHHEIM France Tel.: (33) 03 88 62 52 60 Fax: (33) 03 88 62 26 81 Email: [email protected] Strem Chemicals, Inc. Postfach 1215 77672 KEHL Germany Telefon: 0 78 51/ 7 58 79 Email: info.europe@s...

متن کامل

A simple flow-injection method for the determination of blood glucose using a Technicon immobilized enzyme coil

The applicability of a single-channel flow-injection system with immobilized enzyme coil (Technicon) and UV detection to the determination of glucose is described. The method was used for a pure glucose solution and for serum. The detection limit was 0.10 mM, the rate of determination was 20-40 per hour and the precision was satisfactory. The system is very simple and practical when many analys...

متن کامل

Flow Injection Turbidimetric Determination of Acetylcysteine in Pharmaceutical Formulations Using Silver Nitrate as Precipitant Reagent

Um procedimento de análise por injeção em fluxo turbidimétrico simples, exato e preciso é descrito para determinação de acetilcisteína em formulações farmacêuticas. O procedimento é baseado na precipitação da acetilcisteína com solução de nitrato de prata em meio ácido e o sal insolúvel produzido foi monitorado em 410 nm. A curva analítica para a acetilcisteína foi linear no intervalo de concen...

متن کامل