Flow Field Change before Onset of Flow Separation
نویسندگان
چکیده
منابع مشابه
Erythrocyte Separation Using Gravitational Field Flow Effect
This research aims to simulate a gravity flow fractionation—the process to fractionate erythrocytes through gravitational field using ANSYS simulation software. A particular microfluidic channel was designed as a separation device. The gravitational equilibrium conditions of the erythrocytes and gravitational field as the parameters were chosen, then deriving the erythrocytes’ path through nume...
متن کاملCell separation by dielectrophoretic field-flow-fractionation.
Dielectrophoretic field-flow-fractionation (DEP-FFF) was applied to several clinically relevant cell separation problems, including the purging of human breast cancer cells from normal T-lymphocytes and from CD34+ hematopoietic stem cells, the separation of the major leukocyte subpopulations, and the enrichment of leukocytes from blood. Cell separations were achieved in a thin chamber equipped ...
متن کاملCellular Separation via Dielectrophoretic Field-Flow-Fractionation
I present a brief review of a cellular separation technique known as dielectrophoretic field-flowfractionation. The technique relies upon suspending different cells at different heights within a laminar flow profile. The differentially suspended cells, thus, travel at different speeds and elute from the flow chamber at different times resulting in successful separation. An alternate fabrication...
متن کاملInfluence of flow separation location on phonation onset.
The influence of flow separation location on eigenmode synchronization and phonation onset was investigated in a two-dimensional, aeroelastic, continuum model of phonation. A linear stability analysis showed that flow separation played a critical role in initiating eigenmode synchronization and phonation. For a given glottal configuration, a small variation in the flow separation location along...
متن کاملEffect of Temperature on Particle Separation in Hollow Fiber Flow Field-Flow Fractionation
Ž . Abstract: Hollow fiber flow field-flow fractionation HF-FlFFF has been tested Ž . by varying the temperature 21]738C to increase separation speed with reduced lift forces. It has been experimentally shown that the separation time of 0.050]0.426-mm polystyrene latex standards can be reduced approximately by half, at 598C, compared to the separation at room temperature. In addition, the resol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Fluid Machinery and Systems
سال: 2009
ISSN: 1882-9554
DOI: 10.5293/ijfms.2009.2.3.215