Flow Characteristics of Drag-Reducing Surfactant Solutions

نویسندگان

چکیده

The objective of this study is to clarify the flow characteristics drag-reducing and elucidate mechanism underlying phenomenon. surfactant counter ion we used were Lipothoquad O/12 sodium salicylate, respectively. drag reduction rate ( DR %) was measured by using a recirculating system with diameter 25.6 mm. We also solutions different concentrations temperatures particle image velocimetry (PIV). From experimental results, % at an average velocity 2.0 m/s increased from 0 68% as temperature 10 40 °C constant concentration (300 mg/L). contour plot obtained PIV, found that thickness lower-velocity region near pipe wall thick 20 °C, whereas vortex motions seemed controlled 30 °C. On other hand, thickened 25°C. Even if same level effects occurred, patterns quite depending on temperature.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Drag Reduction by Surfactant Solutions in Gravity Driven Flow Systems

Efflux time measurements are carried out for gravity draining of a liquid from a large cylindrical tank (where the flow is essentially laminar) through single exit pipe in the absence and presence of Cetyl Pyridinium Chloride (CPC) surfactant solutions. The variables considered are initial height of liquid in the tank, dia. of tank, length of the exit pipe and concentration of surfactant. T...

متن کامل

Measurement of temperature profiles in turbulent pipe flow of polymer and surfactant drag-reducing solutions

A device was built to measure temperature profiles of turbulent pipe flows of various drag-reducing fluids. It is easy to use and reliable. We measured temperature profiles over a range of conditions leading to accurate measurements down to y+ 10, for tests carried over Reynolds numbers Re between 10 000 and 90 000. The effects of high heat fluxes and buoyancy, in particular, were quantified to...

متن کامل

drag reduction by surfactant solutions in gravity driven flow systems

efflux time measurements are carried out for gravity draining of a liquid from a large cylindrical tank (where the flow is essentially laminar) through single exit pipe in the absence and presence of cetyl pyridinium chloride (cpc) surfactant solutions. the variables considered are initial height of liquid in the tank, dia. of tank, length of the exit pipe and concentration of surfactant. the d...

متن کامل

Drag Reduction by Anionic Surfactant Solutions in Gravity Driven Flow System

This paper presents efflux time experiments performed in the absence and presence of aqueous solutions of Drag Reducing Agents (DRAs) when a liquid is emptied from a large open cylindrical storage tank through an exit piping system. The drag reducing agents studied are Dodecyl benzene sulfonate anionic surfactant and a mixed solution of surfactant and sodium chloride counter ion. The variab...

متن کامل

drag reduction by anionic surfactant solutions in gravity driven flow system

this paper presents efflux time experiments performed in the absence and presence of aqueous solutions of drag reducing agents (dras) when a liquid is emptied from a large open cylindrical storage tank through an exit piping system. the drag reducing agents studied are dodecyl benzene sulfonate anionic surfactant and a mixed solution of surfactant and sodium chloride counter ion. the variables ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: MATEC web of conferences

سال: 2021

ISSN: ['2261-236X', '2274-7214']

DOI: https://doi.org/10.1051/matecconf/202133302002