A large number of bubbles generated by the air agitation device in an external melting ice storage system can cause disturbance ice–water mixture, which enhance heat transfer and contribute to reduction energy consumption. The structural design optimization is key issue for savings. In this study, influence different orifice spacings diameters on distribution gas–liquid flow field, gas holdup, heat-transfer coefficient, power consumption tank was investigated numerical simulation. simulated results showed that coefficient mixture with should be 3–5 times higher than natural convection when superficial velocity 0.03 m/s. holdup mainly affected spacing, maximum varied from 5.0% 8.2%. When spacing less 150 mm, changed a little horizontal direction, uniformity became worse larger 180 mm. An diameter 3 mm improve air-compressing consumption, decreased approximately 1.62%.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran

Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...

متن کامل

Optimal Energy Reduction Schedules for Ice Storage Air-Conditioning Systems

This paper proposes a hybrid algorithm to solve the optimal energy dispatch of an ice storage air-conditioning system. Based on a real air-conditioning system, the data, including the return temperature of chilled water, the supply temperature of chilled water, the return temperature of ice storage water, and the supply temperature of ice storage water, are measured. The least-squares regressio...

متن کامل

Heat transfer and friction characteristics of air flow in microtubes

Several researches dealing with the single-phase forced convection heat transfer inside microchannels have been published in the past decades. The performance of liquid flow has been proved that agrees with the conventional correlations very well. However, owing to the low heat transfer coefficient of gaseous flow, it is more difficult to eliminate the effects of thermal shunt and heat loss tha...

متن کامل

Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

متن کامل

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2022

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en15165918