Flow and Vibration in the Small Steam Turbine Last Stage
نویسندگان
چکیده
The paper deals with evaluation of experimental data obtained from the real-size 30 MW output Waste to Energy steam turbine. For many turbine regimes pressures in last stage area were obtained. At same time amplitudes blade tips vibrations measured rotor blades using tip timing system and axial velocity at outlet. are mutually correlated relations analysed between increased vibration values pressure ratios stage. Increased occur mainly when ratio over root is higher than one. In this case there no expansion, but compression presented results contribute understanding processes turbine, for those operation its lower 20 % nominal output, e.g. during island regime.
منابع مشابه
Study of the Effects of Lacing Rods Location on Natural Frequencies in Last Stage Blades of a Steam Turbine
In this study, effects of lacing rods location on natural frequencies of last stage of a Steam Turbine Blades (STBs) have been investigated. STBs are critical and important elements in a turbine as well as power plants. One of the most important parameters in turbine blades is lacing rods location. In this paper, first, a three dimensional (3D) scan was used to produce the geometrical model of ...
متن کاملVibration analysis of a steam turbine blade
ABSTRACT Blade failure is a common problem of a steam turbine and it’s failure in-service results in safety risks, repair cost and non operational revenue losses. Thus, the reliability of these blades is very important for the successful operation of a steam turbine. Dynamic analysis of a steam turbine blade in computational environment is carried out in the present work. In order to gain physi...
متن کاملFault Diagnosis for Steam-flow Exciting Vibration of Ultra Supercritical 1000 MW Steam Turbine
With the increase in thermal power capacity, ultra supercritical units have become the mainstream of power industry. At the same time, with the improvement of the steam parameters and the lengthening of shafting, the production of steam flow excited vibration is frequent in the ultra supercritical units, which may seriously affect the reliability of the unit. This paper has taken steam flow exc...
متن کاملNumerical Modeling of Wet Steam Flow in Steam Turbine Channel
In power station practice, work is extracted from expanding steam in three stages namely High Pressure(HP), Intermediate Pressure(IP) and Low Pressure(LP) turbines. During the expansion process in the LP turbine, the steam cools down and at some stages, it nucleates to become a two-phase mixture. It is well-acknowledged in the literature that the nucleating and wet stages in steam turbines are ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC web of conferences
سال: 2022
ISSN: ['2261-236X', '2274-7214']
DOI: https://doi.org/10.1051/matecconf/202236902001