Flotation Behaviors of Perovskite, Titanaugite, and Magnesium Aluminate Spinel Using Octyl Hydroxamic Acid as the Collector
The flotation behaviors of perovskite, titanaugite, and magnesium aluminate spinel (MA-spinel), using octyl hydroxamic acid (OHA) as the collector, were investigated using microflotation experiments, zeta-potential measurements, Fourier transform infrared (FT-IR) analyses, X-ray photoelectron spectroscopy (XPS) analyses, and flotation experiments on artificially mixed minerals. The microflotati...
متن کاملInvestigating the effects of particle size and dosage of talc nanoparticles as a novel solid collector in quartz flotation
In this study, hydrophobic talc nanoparticles were applied as a novel class of solid flotation collector. The aim of this work was to understand the effect of talc nanoparticles size and dosage on the quartz flotation recovery. X-ray analysis, dynamic light scattering, and scanning electron microscopy were conducted. Flotation tests were performed in modified a Hallimond flotation cell. The Zet...
متن کاملResearch on Emulsified Tyre Pyrolysis Oil as a Coal Flotation Collector
In this paper the possibility of using the pyrolysis oil derived from waste tyres as a collector in flotation of coal was evaluated. The pyrolysis oil was obtained at the initial and final pyrolysis temperatures of 400 and 700 C, respectively, and the heat holding time of 30 min. Flotation results indicated that the pyrolysis oil emulsion showed stronger collecting ability than diesel and the c...
متن کاملsynthesis of amido alkylnaphthols using nano-magnetic particles and surfactants
we used dbsa and nano-magnetic for the synthesis of amido alkylnaphtols.
15 صفحه اولInteractional effects of bubble size, particle size, and collector dosage on bubble loading in column flotation
The success of flotation operation depends upon the thriving interactions of chemical and physical variables. In this work, the effects of particle size, bubble size, and collector dosage on the bubble loading in a continuous flotation column were investigated. In other words, this work was mainly concerned with the evaluation of the true flotation response to the changes in the operating varia...