Flexible Power Regulation and Limitation of Voltage Source Inverters under Unbalanced Grid Faults

نویسندگان

چکیده

This paper develops a flexible power regulation and limitation strategy of voltage source inverters (VSIs) under unbalanced grid faults. When the classical theory is used faults, oscillations current distortions are inevitable. In proposed strategy, extended introduced to compute feedbacks together with theory. Based on combination theory, can achieve sinusoidal provision between three common targets, i.e., constant active power, balanced current, reactive power. Meanwhile, associated limiter, which capable keep currents pre-defined threshold maximum apparent for better utilization inverter capacity. With this rated capacity fully both provisions Using limitation, VSI avoid overcurrent tripping flexibly regulate its All conclusions verified by real-time hardware-in-loop tests.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

Control of Grid Integrated Voltage Source Converters under Unbalanced Conditions

............................................................................................................................................... I PREFACE................................................................................................................................................ III CONTENT ..........................................................................................

متن کامل

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

متن کامل

Flexible Power Regulation of Grid-Connected Inverters for PV Systems Using Model Predictive Direct Power Control

This paper presents a Model Predictive Direct Power Control (MPDPC) strategy for a gridconnected inverter used in a photovoltaic system, as found in many distributed generating installations. The controller uses a system model to predict the system behavior at each sampling instant. Using a cost function, the voltage vector with least power ripple is generated. The resultant voltage vector is a...

متن کامل

A model-based PDPC method for control of BDFRG under unbalanced grid voltage condition using power compensation strategy

Brushless doubly fed reluctance generator (BDFRG) has been recently suggested as a wind generator. Different control methods are presented in literature for the BDFRG, but there is a gap on control under unbalanced grid voltage condition (UGVC). This paper presents a predictive direct power control (PDPC) method for the BDFRG under UGVC. The proposed PDPC method is based on power compensation s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: CES transactions on electrical machines and systems

سال: 2022

ISSN: ['2096-3564']