Model for Predicting DC Flashover Voltage of Pre-Contaminated and Ice-Covered Long Insulator Strings
In the current study, a multi-arc predicting model for DC critical flashover voltage of iced and pre-contaminated long insulator strings under low atmospheric pressure is developed. The model is composed of a series of different polarity surface arcs, icicle-icicle air gap arcs, and residual layer resistance. The calculation method of the residual resistance of the ice layer under DC multi-arc ...
متن کاملDC Flashover Performance of Ice-Covered Composite Insulators with Parallel Air Gaps
DC flashover performance of ice-covered composite insulators with a parallel air gap (CI/PAG) is an important technical consideration when such insulators are used to isolate ground wires for the purpose of DC ice-melting. Tests on tension and suspension types of CI/PAG were thus carried out in the artificial climate chamber to investigate their DC icing flashover performance. The influences of...
متن کاملDevelopment of a Bio-inspired Live-Line Cleaning Robot for Suspension Insulator Strings
Exposed porcelain insulator strings need regular cleaning to prevent power failures caused by flashovers from occurring. Live-line cleaning of insulators using robot technology is an alternative and novel approach to removing the contaminants on the surfaces of the insulator. This paper presents a live-line insulator cleaning robot for suspension insulator strings in 500kV power transmission li...
متن کاملAnalysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)
Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...
متن کاملImpact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity
One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...