Flashover Model for Arcing Horns and Transmission Line Arresters
نویسندگان
چکیده
منابع مشابه
Electric Transmission Line Flashover Prediction System
This is a project report from the Power Systems Engineering Research Center (PSERC). PSERC is a multi-university Center conducting research on challenges facing a restructuring electric power industry and educating the next generation of power engineers. More information about PSERC can be found at the Center's website: and major advisor in the preparation of the thesis. We express our apprecia...
متن کاملSurge arresters' circuit models review and their application to a Hellenic 150 kV transmission line
Metal oxide surge arresters are used to protect medium and high voltage systems and equipment against lightning and switching overvoltages. Measurements of the residual voltage of the metal oxide surge arresters indicate dynamic characteristics with the residual voltage to increase as the current front time descends and the residual voltage to reach its maximum, before the arrester current reac...
متن کاملArcing Fault Detection and Fault Location on Hv Transmission Lines
In this paper a new numerical algorithm for fault distance calculation and arcing fault recognition, based on one terminal data and derived in the time domain, is presented. The algorithm is derived for the case of most frequent single-phase line to ground fault. The faulted phase voltage is modelled as a serial connection of the fault resistance and the arc voltage. The fault distance and the ...
متن کاملSputter Erosion Model of Arcing Contact Materials
The sputter erosion of arcing contacts is a very complex phenomenon, which is determined by the interaction between electromagnetic force, heat conduction and surface tension of liquid metal. A new model for evaluating the sputter erosion of electrodes is described in this paper, which is based on the electromagnetic forces against the molten pool, flowing velocity, kinetic energy and the surfa...
متن کاملComparison of Exact Analysis and Steplines Approximation for Externally Excited Exponential Transmission Line
In the present paper, the problem of externally excited exponential transmission line hasbeen solved analytically in frequency domain using a simple approach. Then steplines approximationas a first order approximation for the problem of externally excited nonuniform transmission lines ingeneral and exponentially tapered transmission line (ETL) as a special case has been presented.Finally the tw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1992
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1990.112.12_1085