Fixation of Sacroiliac Fraktur-Luxation Using Plate 2.0 with screw 2.0 mm cortical self-tapping and 2.7 mm cortical non self-tapping

نویسندگان

چکیده

The Mixed Shih-Tzu dog, 3 years old and 4.3 kg body weight, had clinical signs of unable to stand, both rear limbs suffer from diplegic lameness so that they are only able rely on forelimbs. owner said her dog is traumatized by a four-wheeled vehicle. results blood profile before surgery showed physiological, an increase in leukocyte cells 18.83 x103/µL. radiographic examination with ventral-dorsal position shows oblique fractures the pelvic dexter dislocation sacroiliac sinister bone. method handling used was open reduction internal fixation (ORIF) using 2.0 veterinary cuttable plate (VCP) bone mm cortical self-tapping screw for 2.7 non-self-tapping dislocations. walked good progress one week after ORIF, based post-operative examinations, fracture-dislocation VCP fracture non provides excellent stabilization no visible complications.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

       Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize th...

متن کامل

Bolted Timber Joints with Self-tapping Screws

The use of self-tapping screws with continuous threads in the joint area as a reinforcement to avoid splitting of timber members is studied. A theoretical model is developed to calculate the stress distribution around a pin-loaded hole in a timber joint, to predict brittle failure modes in bolted connections and to calculate the load in the reinforcing screws. Laboratory experiments on reinforc...

متن کامل

Use of self-tapping metal screws for temporary fixation of a resorbable plate system in maxillofacial surgery.

Resorbable plate systems have been used in maxillofacial surgery to obviate the need for plate removal. However, resorbable plates and screws are very costly, and refixation with additional screws may be necessary when reduction or repositioning of the bone segment is inaccurate. Here we report the use of self-tapping metal screws for temporary fixation of a resorbable plating system in maxillo...

متن کامل

treatment of displaced sacroiliac fracture using the lateral window for short plate buttress reduction and percutaneous sacroiliac screw fixation.

fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. we describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize the fragm...

متن کامل

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jurnal Sain Veteriner

سال: 2022

ISSN: ['2443-1583', '2407-3733']

DOI: https://doi.org/10.22146/jsv.53112