Fixation of aortic ball valve prosthesis (Starr-Edwards).

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixation of aortic ball valve prosthesis (Starr-Edwards).

The technique of fixation of a ball valve prosthesis in the area of the non-coronary cusp by bringing the sutures from the collar of the prosthesis out through the wall of the aorta and tying them over strips of dacron has been discussed by Starr, Edwards, McCord, and Griswold (1963), and advocated by Effler, Groves, and Favaloro (1964). We have never in our first 100 operated cases seen a leak...

متن کامل

Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic--no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial...

متن کامل

Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...

متن کامل

Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...

متن کامل

Late thrombotic obstruction of Starr-Edwards tricuspid valve prosthesis.

significant number of patients undergoing surA gery for valvular hea, disease suffer from rheumatic involvement or functional insufficiency of the tricuspid valve necessitating its replacement with a prosthe~is.~.' Follow-up studies indicate few significant postoperative complications related to the prosthetic tricuspid ~ a l v e . ~ . ~ Life-threatening obstruction of the prosthesis by thrombu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thorax

سال: 1966

ISSN: 0040-6376

DOI: 10.1136/thx.21.6.529