Five-level inverter scheme for an induction motor drive with simultaneous elimination of common-mode voltage and DC-link capacitor voltage imbalance

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Five-level inverter scheme for an induction motor drive with simultaneous elimination of common- mode voltage and DC-link capacitor voltage imbalance

Abstract: The simultaneous elimination of common-mode voltage and DC-link capacitor voltage imbalance is achieved in a five-level inverter scheme for an induction motor drive throughout its operating range. A dual five-level inverter-fed open-end-winding induction motor structure is used for the proposed drive. Initially, the operating limitations of achieving this dual task for the fivelevel i...

متن کامل

Three-level inverter configuration with common- mode voltage elimination for induction motor drive

A scheme for a three-level voltage space phasor generation with common-mode voltage elimination is proposed. An open-end-winding induction motor, fed from both ends by two threelevel inverters, which are realised by a cascading two two-level inverter, is used in this configuration. The voltage space vectors of individual three-level inverters, which generate the same commonmode voltage in the i...

متن کامل

Space Vector Pulse Width Modulation with Reduced Common Mode Voltage and Current Losses for Six-Phase Induction Motor Drive with Three-Level Inverter

Common-mode voltage (CMV) generated by the inverter causes motor bearing failures in multiphase drives.On the other hand, presence of undesired z-component currents in six-phase induction machine (SPIM) leads to extra current losses and have to be considered in pulse width modulation (PWM) techniques. In this paper, it is shown that the presence of z-component currents and CMV in six phase driv...

متن کامل

Space Vector Modulation Techniques for Common mode Voltage Elimination in the Three- level Voltage Source Inverter

AbstractThe low common mode voltage vector modulation technique for the three-level cascaded voltage source inverter is presented in the paper. The large number of available states for multilevel inverters can make implementation vector control strategies complicated. The main characteristic of the proposed modulation technique is its simplicity of implementation due to the fact that any availa...

متن کامل

UPQC for Power Quality Improvement of Induction Motor Drive with Reduced DC Link Voltage

The main aim of this project is ,this topology enables UPQC to have a reduced dc-link voltage without compromising its compensation capability. Three-phase, four-wire unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEE Proceedings - Electric Power Applications

سال: 2005

ISSN: 1350-2352

DOI: 10.1049/ip-epa:20050166