Fitting Response Curves for Radioimmunoassays or Immunoradiometric Assays
نویسندگان
چکیده
منابع مشابه
Statistical quality control and routine data processing for radioimmunoassays and immunoradiometric assays.
Numerous methods are available for the graphical display of radioimmunoassay dose-response curves, for curve-fitting and dose interpolation, for statistical quality control, and for automation and computerization of data processing. The relative merits of these approaches are discussed. Minimal requirements for radioimmunoassay data-processing systems are presented. The features of an “ideal” s...
متن کاملA hierarchical approach for fitting curves to response time measurements.
Understanding how response time (RT) changes with manipulations has been critical in distinguishing among theories in cognition. It is well known that aggregating data distorts functional relationships (e.g., Estes, 1956). Less well appreciated is a second pitfall: Minimizing squared errors (i.e., OLS regression) also distorts estimated functional forms with RT data. We discuss three properties...
متن کاملFitting photosynthetic carbon dioxide response curves for C(3) leaves.
Photosynthetic responses to carbon dioxide concentration can provide data on a number of important parameters related to leaf physiology. Methods for fitting a model to such data are briefly described. The method will fit the following parameters: V(cmax), J, TPU, R(d) and g(m)[maximum carboxylation rate allowed by ribulose 1.5-bisphosphate carboxylase/oxygenase (Rubisco), rate of photosyntheti...
متن کاملThree commercial immunoradiometric "kit" assays for serum ferritin evaluated.
We evaluated three commercially available immunoradiometric assays for serum ferritin, with particular emphasis on the statistical validity of the results. The data show that it was unusual (a) for dose/response relationships of the standards to be linear over the whole concentration range suggested by the manufacturers and (b) for dose/response relationships of test sera to parallel those of t...
متن کاملPrenatal diagnosis of classic hemophilia (hemophilia A) by immunoradiometric assays.
During the period from 1978 to 1983, 92 pregnancies have been evaluated by fetoscopy for the prenatal diagnosis of hemophilia A. Satisfactory fetal plasma samples were obtained in 80 instances and the diagnosis--or exclusion--of hemophilia was made by immunoradiometric assay of the factor VIII coagulant protein (VIII:CAg). The accuracy of the diagnosis established by fetoscopy has been verified...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry and Laboratory Medicine
سال: 1994
ISSN: 1434-6621,1437-4331
DOI: 10.1515/cclm.1994.32.11.873