First Surgical Melody Valve-In-Valve Implantation for Early Degeneration in Mitral Position
نویسندگان
چکیده
منابع مشابه
Failed valve-in-valve transcatheter mitral valve implantation.
A 73-year old man underwent trans-septal anterograde implantation of a 26-mm Sapien-XT valve (Edwards Lifesciences, CA, USA) to treat a degenerated 27-mm Carpentier-Edwards bioprosthesis. During the follow-up, the patient experienced severe haemolysis with moderate-to-severe inter-valvular leak, and fluoroscopy revealed possible incomplete apposition of the Sapien-XT (Fig. 1). Reoperation was p...
متن کاملEffect of position on echocardiographic diagnosis of mitral valve prolapse
Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...
متن کاملTranscatheter transapical valve-in-valve implantation for degenerated mitral bioprosthesis
A 76-year-old woman with a history of aortic and mitral valve (Mosaic 19 mm; Hancock II 25 mm bioprosthesis, Medtronic Inc., Minneapolis, Minnesota) replacement and former coronary artery bypass grafting in 2010 (left internal mammary artery-left anterior descending artery (LIMA-LAD), aorta-obtuse marginal coronary artery (Ao-OM)) was admitted to our hospital with recurrent pulmonary edema. Her...
متن کاملTransapical mitral valve implantation: the Lutter valve
The development of transcatheter techniques for treatment of severe mitral valve regurgitation in the beating heart is focus of recent research. An off-pump treatment technique poses great benefits, particularly for multimorbid patients, often being non-compliant to the gold standard treatment, being open heart surgery with use of a cardiopulmonary bypass. Thereto, two approaches are being fo...
متن کاملTranscatheter Mitral Valve Implantation
T he rationale for the development of a transcatheter mitral valve implantation (tMVI) procedure, either percutaneous or via minimally invasive surgery (MIS), arose from consideration of several key surgical concepts. First, mitral valve replacement is the most effective modality and the gold standard procedure for reliably reducing mitral regurgitation (MR). The efficacy and risks of mitral va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Annals of Thoracic Surgery
سال: 2018
ISSN: 0003-4975
DOI: 10.1016/j.athoracsur.2017.10.024