First results from a 760-GW linear transformer driver module for Z-pinch research

نویسندگان

چکیده

In this paper, the results of tests on a 0.76-TW linear transformer driver (LTD) module for Z-pinch research are presented first time. Ten LTD cavities, each generating 1-MA/90-kV pulse matched load, were connected in series with magnetically insulated voltage adder to drive e-beam diode. Three inner stalks different radii tested, and indicate that output parameters ten cavities sensitive cathode radii. As an intermediate step, high-current 832 kV/912 kA/130 ns was obtained To date, is maximum power generated directly by fast mega-ampere current output.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

250 kA compact linear transformer driver for wire array z-pinch loads

We present the application of a short rise ( 150 ns) 250 kA linear transformer driver (LTD) to wire array z-pinch loads for the first time. The generator is a modification of a previous driver in which a new conical power feed provides a low inductance coupling to wire loads. Performance of the new design using both short circuit and plasma loads is presented and discussed. The final design del...

متن کامل

Shaping the output pulse of a linear-transformer-driver module

We demonstrate that a wide variety of current-pulse shapes can be generated using a linear-transformerdriver (LTD) module that drives an internal water-insulated transmission line. The shapes are produced by varying the timing and initial charge voltage of each of the module’s cavities. The LTD-driven accelerator architecture outlined in [Phys. Rev. ST Accel. Beams 10, 030401 (2007)] provides a...

متن کامل

760-766 Gw S-o 04

In hydrogeological investigations, the scale at which model parameters (e.g., hydraulic conductivity) are measured is usually quite different from the scale at which heads and contaminant concentrations are measured. The scale of grid blocks used in numerical simulations is usually different from the aforementioned two scales. However, measured concentrations and heads are used for calibration ...

متن کامل

Optimum driving a Z-pinch for soft X-Ray lasers

A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...

متن کامل

Compact 810 kA linear transformer driver cavity

We are performing experiments with a 92-kV, 810-kA, 74.6-GW linear transformer driver (LTD) cavity. This cavity generates a 100 ns power pulse from DC-charged capacitors in a single step. Our experiments start with an existing 100-kV, 490-kA LTD cavity and are making a number of improvements to it that are aimed at increasing the cavity’s peak output power and better understanding its operation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Matter and Radiation at Extremes

سال: 2021

ISSN: ['2468-2047', '2468-080X']