Fire resistance of cold‐formed steel framed shear walls under various fire scenarios

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

non-linear study of various slit shear walls in steel structures

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

15 صفحه اول

Behavior of Steel-Sheathed Shear Walls Subjected to Seismic and Fire Loads.

A series of tests was conducted on six 2.7 m × 3.7 m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear deformation and fire exposure to study the influence of multi-hazard interactions on the later...

متن کامل

Design considerations for fire resistance of lightweight-framed assemblies

The effects of a number of design parameters have been investigated including the types of cavity insulation, resilient channels, gypsum board thickness, the number of gypsum board layers, stud arrangements, and type of framing. The results have shown that the main factors that affected the performance of stud wall assemblies were the type of insulation and the number of gypsum board layers. In...

متن کامل

Computation of Structural Fire Resistance of Steel Sections

The main object of this study is to compute the structural fire resistance for several steel members under different loading conditions. This is done in chapter 4 using two advanced calculation models. Chapter 1 contains prescriptions according to European codes, needed for this research. In Chapter 2 the notion of structural fire resistance is explained and also information about the types of ...

متن کامل

Stainless steel structures in fire

The initial material cost of structural stainless steel is about four times that of structural carbon steel, due largely to the expense of the alloying elements and the relatively low volume of production. Given broadly similar structural performance, additional areas of benefit need to be identified and exploited in order to establish stainless steel as a viable alternative material for constr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Fire and Materials

سال: 2019

ISSN: 0308-0501,1099-1018

DOI: 10.1002/fam.2744