Fire performance of cold-formed steel wall panels and prediction of their fire resistance rating
نویسندگان
چکیده
منابع مشابه
Review: development of performance-based fire design for cold-formed steel
Performance-based fire design for cold-formed steel systems is in its infancy. This paper brings together existing research on cold-formed steel materials, members, and assemblages at elevated temperatures; and complementary analysis and design methods necessary for the development of analysis-based design for cold-formed steel systems under fire. Cold-formed steel systems have become popular i...
متن کاملThe Fire Performance of Exposed Timber Panels
Cross-laminated timber is increasingly being used in the construction of high-rise buildings due to its simple manufacturing system. In term of fire resistance, cross-laminated timber panels are promoted as having excellent fire resistance, comparable to that of non-combustible materials and to heavy timber construction, due to the ability of thick wood assemblies to char slowly at a predictabl...
متن کاملAnalysis of Sheathed Cold-Formed Steel Wall Studs
The strength of sheathed wall systems is substantially greater than unsheathed walls with the same studs. Testing on studs sheathed on both sides with dry gypsum board demonstrate strength increases as large as 70% over unsheathed studs (Miller and Peköz 1993, Miller and Peköz 1994). The current AISI Specification for sheathed wall stud systems are complicated, only apply when the sheathing is ...
متن کاملComputation of Structural Fire Resistance of Steel Sections
The main object of this study is to compute the structural fire resistance for several steel members under different loading conditions. This is done in chapter 4 using two advanced calculation models. Chapter 1 contains prescriptions according to European codes, needed for this research. In Chapter 2 the notion of structural fire resistance is explained and also information about the types of ...
متن کاملExperimental Investigation on Cold-formed Steel Wall Plate System
A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped Cchannel. The lipp...