Fire design of slim‐floor beams
نویسندگان
چکیده
منابع مشابه
Fire resistance of FRP reinforced glulam beams
Thin laminates made of high-strength pultruded fiber reinforced polymers (FRP) are increasingly being used to reinforce glue-laminated timber (glulam) beams, creating a new composite glulam (FRP glulam) significantly stronger in bending than a conventional (unreinforced) glulam of equal size. Large timber members have long been recognized for maintaining structural integrity in fires and this p...
متن کاملEurocode 5 design in comparison with fire resistance tests of unprotected timber beams
It is generally recognized that heavy timber in fire conditions demonstrates high structural performance. Exposed timber chars which functions as an isolative layer which protects the inner material from heat and loss of load bearing capacity. Char has no significant strength, and therefore, as the char layer grows, the load bearing capacity of the timber member reduces under sustained fire con...
متن کاملFinite Element Modeling of Reinforced Concrete Beams Exposed to Fire
Abstract: The practical implementation of performance-based fire safety design of reinforced concrete (RC) structures hinges on the availability of accurate numerical simulation tools for the behavior of RC members exposed to fire. This paper presents a three-dimensional (3D) finite element (FE) model for the accurate prediction of both the thermal and the mechanical behavior of RC beams expose...
متن کاملDesign of a Fire Susceptibility Index for fire risk monitoring
Wildfire risk assessment has traditionally been carried out using models based on meteorological parameters measured at spatially sparse weather stations. Remote sensing techniques can offer a cost effective way of esimating the required parameters such as fuel moisture and fuel temperature in near-real time. Moreover remote sensing can provide wide area coverage and thus circumvent errors intr...
متن کاملDesign of composite beams with web openings
ao"length of opening dh, dl"distance from top of steel section to centroid of concrete force at high and low moment ends of the opening, respectively dr"distance from outside edge of flange to centroid of reinforcement *b"maximum bending deflection for unperforated beam *m,b"maximum bending deflection for a member with an opening Fy"yield stress of steel FM y"reduced axial strength of steel in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Stahlbau
سال: 2019
ISSN: 0038-9145,1437-1049
DOI: 10.1002/stab.201900030