Finite element analysis of concrete-filled steel tube (CFST) columns with circular sections under eccentric load
نویسندگان
چکیده
منابع مشابه
Nonlinear finite element analysis of Concrete Filled Steel Tube (CFST) columns under projectile impact loading
This paper presents a three dimensional nonlinear finite element analysis for Concrete Filled Steel Tube (CFST) columns subjected to lateral impact load. The finite element models were developed using commercial code ABAQUS/Explicit, which were validated against the experimental results. The study has been carried out to examine the influence of several parameters such as the length of the tube...
متن کاملAnalysis of Thin-Walled Steel Sections Filled with Concrete Using Non-Linear Finite Element Method
Being economical and performing well under cyclic loads, steel sections filled with concrete have been widely used in structural buildings. Extensive studies and experiments have been conducted to investigate the influence of different parameters and loadings on the behavior of these structural components. Based on the data available from previous experiments and studies, this paper discusses t...
متن کاملAnalysis of Thin-Walled Steel Sections Filled with Concrete Using Non-Linear Finite Element Method
Being economical and performing well under cyclic loads, steel sections filled with concrete have been widely used in structural buildings. Extensive studies and experiments have been conducted to investigate the influence of different parameters and loadings on the behavior of these structural components. Based on the data available from previous experiments and studies, this paper discusses t...
متن کاملresearch behavior of concrete filled steel tube columns, cfst
concrete filled steel tube columns (cfst) are a kind of composite columns according to advantages of cfst relative to reinforced concrete and steel columns. use of these materials is common in recent years especially in high building, unnecessary of molding, high ductility, proportionate resistance with low volume, economical, low deformation relative to steel columns are among advantages. in t...
متن کاملFinite Element Analysis for CFST Columns under Blast Loading
The columns of frame structures are the key load-bearing components and the exterior columns are susceptible to attack in terrorist blasts. When subjected to blast loads, the columns would suffer a loss of bearing capacity to a certain extent due to the damage imparted which may lead to their collapse and even cause the progressive collapse of the whole structure . The concrete-filled steel col...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2017
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2017.06.064