Finite Control Set Model Predictive Control for a Three-Phase Shunt Active Power Filter with a Kalman Filter-Based Estimation
نویسندگان
چکیده
منابع مشابه
Finite Control Set Model Predictive Control for a Three-Phase Shunt Active Power Filter with a Kalman Filter-Based Estimation
In this paper, the finite control set model predictive control is combined with the vector operation technique to be applied in the control of a three-phase active power filter. Typically, in the finite control set technique applied to three-phase power converters, eight different vectors are considered in order to obtain the optimum control signal by minimizing a cost function. On the other ha...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملA Comparative Performance Analysis of Four Control Algorithms for a Three Phase Shunt Active Power Filter
Shunt Active Power Filters (SAPFs) represent the most important and widely used filter in industrial purposes due to the fact that, they not only eliminate the harmonic current with a neglected amount of active fundamental current supplied to compensate system losses, but also they are suitable for a wide range of power ratings. One of the key issues for a proper implementation of an active fil...
متن کاملa novel active power filter control methodology
this paper presents a new control methodology for active power filters that provide an adaptive online harmonic estimation with partial and selective harmonic reduction schemes, which has been implemented within an integrated controller. the proposed approach is to provide partial and selective reduction of those individual harmonics which exceed the recommended levels as set by regulatory bodi...
متن کاملSingle-Phase Shunt Active Power Filter Using Indirect Control Method
A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2017
ISSN: 1996-1073
DOI: 10.3390/en10101553