Field Experiments on 10 kV Switching Shunt Capacitor Banks Using Ordinary and Phase-Controlled Vacuum Circuit Breakers

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field Experiments on 10 kV Switching Shunt Capacitor Banks Using Ordinary and Phase-Controlled Vacuum Circuit Breakers

During the switching on/off of shunt capacitor banks in substations, vacuum circuit breakers (VCBs) are required to switch off or to switch on the capacitive current. Therefore, the VCBs have to be operated under a harsh condition to ensure the reliability of the equipment. This study presents a complete comparison study of ordinary and phase-controlled VCBs on switching 10 kV shunt capacitor b...

متن کامل

Benefits of Controlled Switching of Medium Voltage Circuit Breakers

This paper describes the benefits of using controlled switching technology on medium voltage circuit breakers. Although this technology has been used on high voltage networks for over 30 years, recent technological advances have permitted the development of a new generation of controlled switching devices for medium voltage. This paper reviews controlled switching device approaches, describes m...

متن کامل

Circuit Breakers Transient Reduction By Using A Dedicated Controlled Switching System

The controlled switching can be applied to any type of commutations. Now there are dedicated controllers which are used more often for the switching of the transport and distribution lines, of the small inductive loads, of the capacitors batteries, or the energizing the no load power transformers. The paper presents a microcontroller (8051 family) based system used to controlled switching of va...

متن کامل

Mechanical Condition Monitoring of Vacuum Circuit Breakers Using Artificial Neural Network

Using the Vibration signatures obtained during the operations as the original data, a mechanical condition monitoring method for vacuum circuit breaker is developed in this paper. The method combined the time-frequency analysis and the condition recognition based on artificial neural network. During preprocessing, the vibration signature was decomposed into individual frequency bands using the ...

متن کامل

Optimal Placement and Sizing of DGs and Shunt Capacitor Banks Simultaneously in Distribution Networks using Particle Swarm Optimization Algorithm Based on Adaptive Learning Strategy

Abstract: Optimization of DG and capacitors is a nonlinear objective optimization problem with equal and unequal constraints, and the efficiency of meta-heuristic methods for solving optimization problems has been proven to any degree of complex it. As the population grows and then electricity consumption increases, the need for generation increases, which further reduces voltage, increases los...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2016

ISSN: 1996-1073

DOI: 10.3390/en9020088