Results of research absorbed dose rate dependence on distance and positioning accuracy standard dosimetric beta-radiation sources at the new AT200 calibration facility (by ATOMTEX SPE) are presented. The non-uniform profile fields created by with strontium-90 + yttrium-90, krypton-85 promethium-147 radionuclides under conditions as specified in ISO/DIS 6980-2:2021(E) international was investigated.
منابع مشابه
Experimental and Simulation Analysis of Radiation of the Beta Emitting Sources in a Magnetic Field
OBJECTIVE The behavior of beta particles under the magnetic field was investigated both theoretically and experimentally based on the assumption of reducing the damage to the normal tissues created by using magnetic field in radionuclide therapy. METHODS A water-filled spherical medium and a beta particle source was formed by using Geant4 simulation software for the theoretical study. After a...
متن کاملA Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter
Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....
متن کاملmetallicity of starburst galaxies in chandra deep field south (cdf-s) , at 0.5
چکیده یکی از پارامترهای اصلی در دنبال کردن تاریخچه ی تشکیل ستاره ها و تحول کهکشان ها، مطالعه ی میزان فراوانی عناصر آن ها است. در این پایان نامه برای مطالعه ی همبستگی میان فراوانی فلزی و جرم ستاره ای کهکشان ها، از داده های طیفی 89 کهکشانِ ستاره زا استفاده شده است. طیف ها توسط طیف نگار فورس2 از میدان ژرف جنوبی چاندرا گرفته شده و جابه جایی به سرخ طیف ها همه بزرگتر از نیم و کوچکتر از یک هستند. جر...
15 صفحه اولEstimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
متن کاملPublic exposure to natural radiation sources (Ramsar Case Study)
Introduction: Human beings are naturally exposed to ionizing radiation in any environment. There are two main contributors to radiation exposures from natural sources: cosmic rays, Cosmo genic radionuclides, and radioactive nuclides that originated in the earth's crust. According to the latest data provided by the United Nations Scientific Committee on the Effects of Atomic Rad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ANRI
سال: 2022
ISSN: ['2075-1338']
DOI: https://doi.org/10.37414/2075-1338-2022-111-4-61-65