Fetal organ dose assessment during pelvic CT examination using Monte Carlo/GATE simulation and pregnancy voxelized phantom Katja

نویسندگان

چکیده

In certain situations where there is a risk of fetal-pelvis disproportion (risk that the baby will not be able to pass through pelvis), pelvic scan examination may prescribed mother at end pregnancy. This assesses dimensions pelvis by measuring various bone diameters. It also provides details information about morphology. Patients are routinely worried unwanted effects on fetus from radiation exposure. Accepting possibility adverse fetal exposure and inability measure directly in vivo [1]. Medical physicists have developed several techniques determine amount reaches fetus. Physicians need understand these methods how numbers they produce relate possible biological this study A 16 helical multi-slice CT scanner was simulated. Full technical specifications were obtained constructor simulated GATE single x-ray beams. Katja voxelized patient phantom, pregnant 24 weeks, scanned with protocol. The code used estimate absorbed effective doses important organs as consequence scanning parameters. purpose use phantom assessed organ dose, dose evaluate related due using Monte Carlo/Gate platform. Fetal 4.8, 6.3 8.2 mSv for 80, 110 130 kV respectively. heart, eye lens, brain 1.61, 1.6 0.8 mGy 80 kV. Since lower than 50 mGy, when exposed teratogenic significant concern [2].

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of organ dose in chest CT examination using Monte Carlo simulation

Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...

متن کامل

measurement of organ dose in chest ct examination using monte carlo simulation

background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

thorax organ dose estimation in computed tomography based on patient ct data using monte carlo simulation

background:  this study presents patient specific and organ dose estimation in computed tomography (ct) imaging of thorax directly from patient ct image using monte carlo simulation.  patient's ct image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. materials and methods: egsnrc /beamnrc monte c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2022

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202235101072