Fetal liver volume measurement by three-dimensional ultrasonography: a preliminary study

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Fetal brain fissures development a three-dimensional ultrasonography study].

PURPOSE to assess the distance of the fetal cerebral fissures from the inner edge of the skull by three-dimensional ultrasonography (3DUS). METHODS this cross-sectional study included 80 women with normal pregnancies between 21st and 34th weeks. The distances between the Sylvian, parieto-occiptal, hippocampus and calcarine fissures and the internal surface of the fetal skull were measured. Fo...

متن کامل

Three-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog

Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...

متن کامل

Reproducibility of fetal limbs volume by three- dimensional ultrasonography utilizing the XI VOCAL method*

OBJECTIVE: To assess the reproducibility of fetal thigh and upper arm volumes measurement by threedimensional ultrasonography utilizing the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. MATERIALS AND METHODS: This reproducibility study enrolled 43 pregnant women with healthy singleton pregnancies between 20 and 37 gestational weeks. The XI VOCAL 10 planes was the met...

متن کامل

Reference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography*

OBJECTIVE To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography. MATERIALS AND METHODS Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sag...

متن کامل

Use of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog

This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ultrasound in Obstetrics and Gynecology

سال: 1998

ISSN: 0960-7692

DOI: 10.1046/j.1469-0705.1998.12020093.x