Fetal Heart Rate Monitoring Casebook: Decreased Fetal Movement
نویسندگان
چکیده
منابع مشابه
The future of fetal heart rate monitoring.
Medical technology is developing at an accelerated rate. Advances and refinement in techniques of electronic fetal heart rate (FHR) monitoring are continually being designed and tested. Many of these show real promise for the future. Never-theless, for the next several years there are two major considerations. First, a more universal application of FHR monitoring i.e., to the "normal" patient ä...
متن کاملCombined electronic fetal heart rate and fetal movement monitor--a preliminary report.
We have tested a new Doppler ultrasound apparatus which registers both fetal movements and fetal heart rate with a single transducer. To evaluate the reliability of the recognition of movements we also observed them simultaneously by real time ultrasound. In 20 patients with normal pregnancies between the 30th and 42nd week of gestation, taking the real time ultrasound as reference the positive...
متن کاملDevelopment of fetal movement--fetal heart rate coupling from 20 weeks through term.
This study documents the development of fetal heart rate (FHR) change in response to fetal movement (FM) in healthy fetuses from 20 weeks' gestational age through term. Thirty-one fetuses received 50 min of Doppler-based monitoring at 20, 24, 28, 32, 36 and 38-39 weeks. FHR and FM were continuously digitized. A coupling index was computed as the percentage of FMs associated with increases in FH...
متن کاملFetal heart rate baseline estimation with analysis of fetal movement signal.
In order to assign appropriate baseline estimation algorithms to different fetal heart rate tracing, a method to evaluate the fetal heart rate (FHR) baseline combining with the fetal movement information was proposed. Fetal actography and tocography were used to extract the fetal movement information. The results showed that the combined method, where the fetal movement detection result was the...
متن کاملFetal heart rate pattern notification guidelines and suggested management algorithm for intrapartum electronic fetal heart rate monitoring.
CONTEXT Numerous randomized controlled trials have demonstrated limited efficacy of intrapartum fetal heart rate monitoring in improving fetal outcome. A potential reason is the wide variability in clinical decision making seen with its use. Standardizing management of variant intrapartum fetal heart rate tracings may reduce this variability and lead to improvement in fetal outcome. OBJECTIVE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Perinatology
سال: 2002
ISSN: 0743-8346,1476-5543
DOI: 10.1038/sj.jp.7210692