Fetal heart rate baseline estimation with analysis of fetal movement signal
نویسندگان
چکیده
منابع مشابه
Fetal heart rate baseline estimation with analysis of fetal movement signal.
In order to assign appropriate baseline estimation algorithms to different fetal heart rate tracing, a method to evaluate the fetal heart rate (FHR) baseline combining with the fetal movement information was proposed. Fetal actography and tocography were used to extract the fetal movement information. The results showed that the combined method, where the fetal movement detection result was the...
متن کاملExtraction of Fetal Heart Rate and Fetal Heart Rate Variability from Mother's ECG Signal
This paper describes a new method for extracting the fetal heart rate (fHR) and the fetal heart rate variability (fHRV) signal non-invasively using abdominal maternal electrocardiogram (mECG) recordings. The extraction is based on the fundamental frequency (Fourier’s) theorem. The fundamental frequency of the mother’s electrocardiogram signal (fo-m) is calculated directly from the abdominal sig...
متن کاملImprovements in fetal heart rate analysis by the removal of maternal-fetal heart rate ambiguities
BACKGROUND Misinterpretation of the maternal heart rate (MHR) as fetal may lead to significant errors in fetal heart rate (FHR) interpretation. In this study we hypothesized that the removal of these MHR-FHR ambiguities would improve FHR analysis during the final hour of labor. METHODS Sixty-one MHR and FHR recordings were simultaneously acquired in the final hour of labor. Removal of MHR-FHR...
متن کاملAutomatic Analysis of Intrapartum Fetal Heart Rate
Doctoral thesis statement for obtaining the academic title of " Doctor " , Resume 23 Shrnutí 24 1 1 Problem introduction Fetal heart activity is the prominent source of information about the fetal well being during delivery. Cardiotocography (CTG) – recording of fetal heart rate (fHR) and uterine contractions (TOCO) enables obstetricians to detect possible ongoing fetal hypoxia, which may occur...
متن کاملApplication of Generalized Filters for Estimation of Fetal Heart Rate Baseline
This paper addresses the problem of impulsive noise cancellation in digital signal area. The myriad and meridian filters are the type of robust filters which are very useful in suppressing the impulsive type of noise. The cost functions of theses filters have very similar structure. In this paper the generalized filter based on Lp norm is presented. The proposed filter operates in a wide range ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bio-Medical Materials and Engineering
سال: 2014
ISSN: 0959-2989,1878-3619
DOI: 10.3233/bme-141205