Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Instantaneous Fetal Heart Rate Extracted from Abdominal and Direct Fetal Electrocardiograms

This work is an attempt to assess the reliability of indirect abdominal electrocardiography as an alternative technique of fetal monitoring. As a reference signal we used the simultaneously acquired direct fetal electrocardiogram. Each recording consisted of four signals acquired from maternal abdomen and the reference signal acquired directly from fetal head. The first stage of our study conce...

متن کامل

Separation of Abdominal Fetal Electrocardiograms in Twin Pregnancy

A combined application of independent component analysis and projective filtering of the time-aligned ECG beats is proposed to solve the problem of fetal ECG extraction from multi-channel maternal abdominal electric signals. The developed method is employed to process the four-channel abdominal signals recorded during twin pregnancy. The signals are complicated mixtures of the maternal ECG, the...

متن کامل

Maternal-fetal heartbeat phase synchronization.

I ntegrated physiological systems under neural control, such as the cardiac and respiratory systems, exhibit complex dynamics with continuous noisy fluctuations even in resting ‘‘equilibrium’’ conditions without external perturbations (1, 2). Advances in analytic methods have made it possible to identify a surprisingly robust temporal organization embedded in physiologic fluctuations, character...

متن کامل

fetal qrs detection in noninvasive abdominal electrocardiograms using principal component analysis and discrete wavelet transforms with signal quality estimation

background: fetal heart rate (fhr) extracted from abdominal electrocardiogram (ecg) is a powerful non-invasive method in appropriately assessing the fetus well-being during pregnancy. despite significant advances in the field of electrocardiography, the analysis of fetal ecg (fecg) signal is considered a challenging issue which is mainly due to low signal to noise ratio (snr) of fecg. objective...

متن کامل

‏‎a comparative study of language learning strategies employmed by bilinguals and monolinguals with reference to attitudes and motivation‎‏

هدف از این تحقیق بررسی برخی عوامل ادراکی واحساسی یعنی استفاده از شیوه های یادگیری زبان ، انگیزه ها ونگرش نسبت به زبان انگلیسی در رابطه با زمینه زبانی زبان آموزان می باشد. هدف بررسی این نکته بود که آیا اختلافی چشمگیر میان زبان آموزان دو زبانه و تک زبانه در میزان استفاده از شیوه های یادگیری زبان ، انگیزه ها نگرش و سطح مهارت زبانی وجود دارد. همچنین سعی شد تا بهترین و موثرترین عوامل پیش بینی کننده ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scientific Data

سال: 2020

ISSN: 2052-4463

DOI: 10.1038/s41597-020-0538-z