Femur Auxetic Meta-Implants with Tuned Micromotion Distribution

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micromotion of Dental Implants: Basic Mechanical Considerations

Micromotion of dental implants may interfere with the process of osseointegration. Using three different types of virtual biomechanical models, varying contact types between implant and bone were simulated, and implant deformation, bone deformation, and stress at the implant-bone interface were recorded under an axial load of 200 N, which reflects a common biting force. Without friction between...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Effective heuristics and meta-heuristics for the quadratic assignment problem with tuned parameters and analytical comparisons

Quadratic assignment problem (QAP) is a well-known problem in the facility location and layout. It belongs to the NP-complete class. There are many heuristic and meta-heuristic methods, which are presented for QAP in the literature. In this paper, we applied 2-opt, greedy 2-opt, 3-opt, greedy 3-opt, and VNZ as heuristic methods and tabu search (TS), simulated annealing, and pa...

متن کامل

Mapping the strain distribution on the proximal femur with titanium and flexible-stemmed implants using digital image correlation.

We implanted titanium and carbon fibre-reinforced plastic (CFRP) femoral prostheses of the same dimensions into five prosthetic femora. An abductor jig was attached and a 1 kN load applied. This was repeated with five control femora. Digital image correlation was used to give a detailed two-dimensional strain map of the medial cortex of the proximal femur. Both implants caused stress shielding ...

متن کامل

The use of Roentgen stereophotogrammetry to study micromotion of orthopaedic implants

Roentgen stereophotogrammetry is the most accurate Roentgen technique for three-dimensional assessment of micromotion of orthopaedic implants. The reported accuracy of Roentgen Stereophotogrammetric Analysis (RSA) ranges between 0.05 and 0.5 mm for translations and between 0.15j and 1.15j for rotations. Because of the high accuracy of RSA, small patient groups are in general sufficient to study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Materials

سال: 2020

ISSN: 1996-1944

DOI: 10.3390/ma14010114