FEM analysis of steel-concrete composite bridges with encased perforated steel strips
نویسندگان
چکیده
منابع مشابه
Steel versus Steel-reinforced Concrete Bridges: Environmental Assessment
Bridge material selection has traditionally been b~ed on e.ngineering and economi~ criteria. With the increasing interest of the public, industry, and government m sustainable:: development, en~lronmental. assessment in construction is becoming more important. However, we need metrtcs and data on deSign alternatives for effective decision making. In this paper, we present results of a life cycl...
متن کاملSteel Concrete Composite Structures: State of Art
The aim of this review article is to examine solutions and challenges associated with composite construction. Structural steel and concrete, each of the two materials can be used to its best advantage and, therefore, composite structures have proved economical in terms of overall cost. Combination of steel and concrete systems has been conceived on the premises that each type of construction of...
متن کاملAnalysis and Design of Steel-Concrete Composite Frame Systems
The lack of clear guidance regarding the value of elastic flexural rigidity (EI) that should be used in the analysis of steel-concrete composite columns is a significant unresolved issue that hinders the design of frame systems that include these members. The common approach of utilizing the rigidity of either the steel or the concrete only tends to be overly conservative. Other approaches that...
متن کاملStrengthening of Scaled Steel-Concrete Composite Girders and Steel Monopole Towers with CFRP
Cost-effective rehabilitation and/or strengthening of steel structures currently demanded by the telecommunications industry and transportation departments. Rehabilitation is often required due to crosssection losses resulting from corrosion damage and strengthening may be required due to changes in the use of a structure. Current strengthening techniques, have several disadvantages including t...
متن کاملFlexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC Web of Conferences
سال: 2020
ISSN: 2261-236X
DOI: 10.1051/matecconf/202031000050