Feasibility of proton-activated implantable markers for proton range verification using PET

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of practical proton-activated implantable markers for proton range verification using PET

Specific Aims: The aim of this research project is to develop a fiducial marker that can be used for in vivo proton range verification following proton therapy. Our group has previously shown the feasibility of using novel elements as proton-activated fiducial markers that can be imaged using an off-site PET scanner (Cho et al 2013). In this research, we will investigate the optimal physical co...

متن کامل

First in situ TOF-PET study using digital photon counters for proton range verification.

Positron emission tomography (PET) is the imaging modality most extensively tested for treatment monitoring in particle therapy. Optimal use of PET in proton therapy requires in situ acquisition of the relatively strong (15)O signal due to its relatively short half-life (~2 min) and high oxygen content in biological tissues, enabling shorter scans that are less sensitive to biological washout. ...

متن کامل

Proton Therapy Verification with PET Imaging

Proton therapy is very sensitive to uncertainties introduced during treatment planning and dose delivery. PET imaging of proton induced positron emitter distributions is the only practical approach for in vivo, in situ verification of proton therapy. This article reviews the current status of proton therapy verification with PET imaging. The different data detecting systems (in-beam, in-room an...

متن کامل

In vivo proton beam range verification using spine MRI changes.

PURPOSE In proton therapy, uncertainty in the location of the distal dose edge can lead to cautious treatment plans that reduce the dosimetric advantage of protons. After radiation exposure, vertebral bone marrow undergoes fatty replacement that is visible on magnetic resonance imaging (MRI). This presents an exciting opportunity to observe radiation dose distribution in vivo. We used quantitat...

متن کامل

Range verification for eye proton therapy based on proton-induced x-ray emissions from implanted metal markers.

Metal fiducial markers are often implanted on the back of the eye before proton therapy to improve target localization and reduce patient setup errors. We aim to detect characteristic x-ray emissions from metal targets during proton therapy to verify the treatment range accuracy. Initially gold was chosen for its biocompatibility properties. Proton-induced x-ray emissions (PIXE) from a 15 mm di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics in Medicine and Biology

سال: 2013

ISSN: 0031-9155,1361-6560

DOI: 10.1088/0031-9155/58/21/7497