Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system

نویسندگان

چکیده

The purpose of this study was to characterize the technical capabilities and feasibility a large field-of-view clinical spectral photon-counting computed tomography (SPCCT) prototype for high-resolution (HR) lung imaging. Measurement modulation transfer function (MTF) acquisition line pairs phantom were performed. An anthropomorphic nodule scanned with standard (120 kVp, 62 mAs), low 11 ultra-low (80 3 mAs) radiation doses. A human volunteer underwent 63 dose scans after approval by ethics committee. HR images reconstructed 1024 matrix, 300 mm field view 0.25 slice thickness using filtered-back projection (FBP) two levels iterative reconstruction (iDose 5 9). conspicuity sharpness various structures (distal airways, vessels, fissures proximal bronchial wall), image noise, overall quality independently analyzed three radiologists compared previous CT examination same performed conventional equipped energy integrating detectors 10 mAs, FBP). Ten percent MTF measured at 22.3 lp/cm cut-off 31 lp/cm. Up 28 depicted. While mixed solid nodules easily depicted on low-dose images, higher iDose thicknesses (1 mm) needed visualize ground-glass components ultra-low-dose images. Standard SPCCT in vivo greater sharpness, quality, similar noise (despite flux reduction 23%) Low-dose or lower but acceptable 89%). demonstrates high resolution human.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical CT

Theoretical considerations predicted the feasibility of K-edge x-ray computed tomography (CT) imaging using energy discriminating detectors with more than two energy bins. This technique enables material-specific imaging in CT, which in combination with high-Z element based contrast agents, opens up possibilities for new medical applications. In this paper, we present a CT system with energy de...

متن کامل

A large field of view two-photon mesoscope with subcellular resolution for in vivo imaging

Imaging is used to map activity across populations of neurons. Microscopes with cellular resolution have small (.

متن کامل

Differential diagnosis of pancreatic cystic masses with the quantitative analysis of spectral CT imaging: Initial results

Background: To retrospectively evaluate whether quantitative information derived from spectral imaging can improve the differential diagnosis of pancreatic cystic masses including pancreatic solid pseudopapillary epithelial neoplasms (SPENs), mucin- producing cysts and pseudocysts. Materials and Methods: From June 2015 to October 2017, 56 patients (22 pseudocysts, 18 mucin-producing cysts and 1...

متن کامل

The effects of extending the spectral information acquired by a photon-counting detector for spectral CT.

Photon-counting x-ray detectors with pulse-height analysis provide spectral information that may improve material decomposition and contrast-to-noise ratio (CNR) in CT images. The number of energy measurements that can be acquired simultaneously on a detector pixel is equal to the number of comparator channels. Some spectral CT designs have a limited number of comparator channels, due to the co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Diagnostic and interventional imaging

سال: 2021

ISSN: ['2211-5684']

DOI: https://doi.org/10.1016/j.diii.2021.01.001