FDT Perimetry for Glaucoma Detection in Comprehensive Health Checkup Service
نویسندگان
چکیده
منابع مشابه
New approach for the glaucoma detection with pupil perimetry
OBJECTIVE To calculate the pattern deviation for identifying abnormal points of pupil perimetry, and also to evaluate the grayscale display for distinguishing glaucomatous pupil field loss (abnormal test points) from normal pupil field (normal test points). METHODS Fourteen patients ranging in age from 51 to 80 years, who had normal-tension glaucoma (6 eyes) and primary open-angle glaucoma (8...
متن کاملComparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.
PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...
متن کاملAutomated perimetry in glaucoma--room for improvement?
et al. The use of vitamin supplements and risk of cataract among US male physicians.
متن کاملComparison of Matrix Frequency-Doubling Technology (FDT) Perimetry with the SWEDISH Interactive Thresholding Algorithm (SITA) Standard Automated Perimetry (SAP) in Mild Glaucoma
This study aimed to compare second-generation frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) in mild glaucoma. Forty-seven eyes of 47 participants who had mild visual field defect by SAP were included in this study. All participants were examined using SITA 24-2 (SITA-SAP) and matrix 24-2 (Matrix-FDT). The correlations of global indices and the number of d...
متن کاملComparative evaluation of oculokinetic perimetry and conventional perimetry in glaucoma.
Oculokinetic perimetry is a new method of visual field assessment in which the patient moves the eye around a central static target to look sequentially at an array of numbers. When fixation on a number is accompanied by disappearance of the central target, that number is deleted from a recording chart. Inversion of the recording chart gives a plot of the central visual field. In this study we ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Ophthalmology
سال: 2020
ISSN: 2090-004X,2090-0058
DOI: 10.1155/2020/4687398