Fault-Tolerant Control of a Nonlinear Process with Input Constraints
A Fault-Tolerant Control (FTC) methodology has been presented for nonlinear processes being imposed by control input constraints. The proposed methodology uses a combination of Feedback Linearization and Model Predictive Control (FLMPC) schemes. The resulting constraints in the transformed process will be dependent on the actual evolving states, making their incorporation in the de...
متن کاملDesign of an Active Approach for Detection, Estimation and Short-Circuit Stator Fault Tolerant Control in Induction Motors
Three phase induction motors have many applications in industries. Consequently, detecting and estimating the fault and compensate it in a way that the faulty induction motor satisfies the predefined goals are important issues. One of the most common faults in induction motors is the short circuit of the stator winding. In this paper, an active fault-tolerant control system is designed and pres...
متن کاملExperimental fault-tolerant control of a PMSM drive
The paper describes a study and an experimental verification of remedial strategies against failures occurring in the inverter power devices of a permanent-magnet synchronous motor drive. The basic idea of this design consists in incorporating a fourth inverter pole, with the same topology and capabilities of the other conventional three poles. This minimal redundant hardware, appropriately con...
متن کاملModelling and Simulation of a Transformer With Inter-turn Fault Including Saturation Effect and Variable Fault Parameters
This investigation deals with a mathematical model for a distribution transformer including saturation effect. To this end, the equations related to a three phase transformer are specified and the effect of an inter-turn fault is included. Naturally by applying an inter-turn fault the inductance and resistance matrix will change. Thus, unknown quantities of inductances and resistances for compl...
متن کاملFault-tolerant Control of a Wind Turbine with Generator Stator Inter-turn Faults
Faults of wind turbine generator electromechanical parts are common and very expensive. This paper introduces a generator fault-tolerant control scheme for variable-speed variable-pitch wind turbines that can be applied regardless to the AC generator used. The focus is on generator stator isolation inter-turn fault that can be diagnosed and characterised before triggering the safety device. An ...