Fault Tolerant Control of Induction Motor Drives Subject to Rotor Resistance Adaptation
نویسندگان
چکیده
منابع مشابه
Online Rotor Resistance Adaptation Of Induction Motor Drive
In this paper an adaptive control systems scheme is used to update the rotor resistance of an induction motor drive. Rotor resistance of the induction motor drive is dependent on the temperature where it is installed for one Induced Draft Fan (I.D Fan) in one of the 500 MW generating thermal power plant. The rotor resistance adaptation is of induction motor drive is achieved through Indirect Fi...
متن کاملSpeed Sensorless Field-Oriented Control of Induction Motor with Rotor Resistance Adaptation
Several field-oriented induction motor drive methods without rotational transducers have been proposed. These methods have a disadvantage that the rotor resistance variation causes an estimation error of the motor speed. Therefore, simultaneous estimation of the motor speed and the rotor resistance is required. This paper presents a method of estimating simultaneously the motor speed and the ro...
متن کاملIndirect Rotor Field-Oriented Control of Fault-Tolerant Drive System for Three-Phase Induction Motor with Rotor Resistance Estimation Using EKF
The performance of an Indirect Rotor Field-Oriented Control (IRFOC) scheme for Induction Motors (IMs) is strongly dependent on the motor parameters especially, rotor resistance. As such, to ensure high performance drive system, the variation of the rotor resistance due to the temperature increase need to be estimated based on the available terminal variables. However, the algorithm used to esti...
متن کاملFault Tolerant Control for Induction Motor Drive Using Descriptor Approach
This paper presents an active fault tolerant control (FTC) strategy for induction motor drive that ensures trajectory tracking and offset the effect of the sensor faults despite the presence of load torque disturbance. The proposed approaches use a fuzzy descriptor observer to estimate simultaneously the system state and the sensor fault. The physical model of induction motor is approximated by...
متن کاملOn Line Determination of Optimal Hysteresis Band Amplitudes in Direct Torque Control of Induction Motor Drives
In conventional direct torque control (DTC) of induction machines, undesirable flux and torque ripples are produced. These occur since non of the selected inverter's voltage vectors are able to generate the exact voltage required to produce the desired changes in the electromagnetic torque and stator flux linkage in most of the switching instances. In addition, when direct torque control is imp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Algerian Journal of Signals and Systems
سال: 2016
ISSN: 2676-1548,2543-3792
DOI: 10.51485/ajss.v1i1.13